FireCADCalc

Resistors in Series and Parallel

Total resistance of up to six resistors connected in series and in parallel, with the current share of each branch; the same sums apply to inductors.

Electrician and wireman licence examinations

Inputs

Examples: 100, 220 and 470 ΩTwo 1 kΩ10, 22, 47, 100, 220 and 470 Ω

Results

Capacitors combine the other way round: in parallel they add, in series their reciprocals add.

Total resistance, all in series869.00Ω
Total resistance, all in parallel5.4524Ω
Resistors counted6.0000
Share of the total current in R₁ (parallel)54.524%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100, 220 and 470 Ω. The inputs, in the units selected above:

InputValue
Resistor 1 (0 = not used)100.00 Ω
Resistor 2 (0 = not used)220.00 Ω
Resistor 3 (0 = not used)470.00 Ω
Resistor 4 (0 = not used)0 Ω
Resistor 5 (0 = not used)0 Ω
Resistor 6 (0 = not used)0 Ω

Applying the formula below gives:

ResultValue
Total resistance, all in series790.00 Ω
Total resistance, all in parallel59.977 Ω
Resistors counted3.0000
Share of the total current in R₁ (parallel)59.977 %

Open this example in the calculator and change any input.

Formula

\(R_s = \sum R_k\)

\(\frac{1}{R_p} = \sum \frac{1}{R_k}\)

\(\frac{I_1}{I} = \frac{R_p}{R_1}\)

Variables

Symbol Meaning SI unit
\(R_1\) Resistor 1 (0 = not used) Ω
\(R_2\) Resistor 2 (0 = not used) Ω
\(R_3\) Resistor 3 (0 = not used) Ω
\(R_4\) Resistor 4 (0 = not used) Ω
\(R_5\) Resistor 5 (0 = not used) Ω
\(R_6\) Resistor 6 (0 = not used) Ω
\(R_s\) Total resistance, all in series Ω
\(R_p\) Total resistance, all in parallel Ω
\(n\) Resistors counted -
\(I_1 / I\) Share of the total current in R₁ (parallel) -

Method and standards

From Kirchhoff's laws: resistances in series carry one current and add; in parallel they share one voltage and their conductances add.

Where it is used

  • Making an odd resistance value from standard ones.
  • Earth electrode groups and parallel cable runs (as a first approximation).
  • Current sharing between parallel paths.

Common mistakes

  • Adding parallel resistances directly.
  • Leaving an unused branch at a small value instead of 0 (not used).
  • Using it for impedances with different phase angles.

Assumptions and limits

  • Pure resistances (or inductors without mutual coupling).
  • Up to six branches.

References

  • Kirchhoff's laws (series and parallel combination of resistances)

Questions and answers

What is 100, 220 and 470 Ω in parallel?

60.0 Ω, less than the smallest; in series they make 790 Ω.

What share of the current goes through the 100 Ω branch?

60 %: in parallel each branch carries R_p/R of the total.

And capacitors?

The other way round: capacitors in parallel add; in series their reciprocals add.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.