FireCADCalc

Maximum Power Transfer Theorem Calculator

Power delivered to a load from a source of given voltage and internal resistance, the efficiency, and the maximum power when the load matches the source.

Inputs

Examples: 12 V, 4 Ω source into 8 ΩMatched: 24 V, 50 Ω into 50 Ω1.5 V cell, 0.3 Ω, into 0.1 Ω

Results

Current3.7500A
Power in the load1.4062W
Efficiency R_L / (R_th + R_L)25.000%
Maximum power (at R_L = R_th)1.8750W
Share of the maximum delivered75.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 12 V, 4 Ω source into 8 Ω. The inputs, in the units selected above:

InputValue
Source (Thévenin) voltage12.000 V
Source (internal) resistance4.0000 Ω
Load resistance8.0000 Ω

Applying the formula below gives:

ResultValue
Current1.0000 A
Power in the load8.0000 W
Efficiency R_L / (R_th + R_L)66.667 %
Maximum power (at R_L = R_th)9.0000 W
Share of the maximum delivered88.889 %

Open this example in the calculator and change any input.

Formula

\(P_L = \frac{V_{th}^2 R_L}{(R_{th} + R_L)^2}, \quad P_{max} = \frac{V_{th}^2}{4 R_{th}}\)

Variables

Symbol Meaning SI unit
\(V_{th}\) Source (Thévenin) voltage V
\(R_{th}\) Source (internal) resistance Ω
\(R_L\) Load resistance Ω
\(I\) Current A
\(P_L\) Power in the load W
\(\eta\) Efficiency R_L / (R_th + R_L) -
\(P_{max}\) Maximum power (at R_L = R_th) W
\(P_L/P_{max}\) Share of the maximum delivered -

Method and standards

Derivative of load power with respect to R_L is zero at R_L = R_th.

Where it is used

  • Audio, RF and sensor matching.
  • Battery internal resistance.

Common mistakes

  • Assuming maximum power means maximum efficiency.

Assumptions and limits

  • Resistive source and load.

References

  • Maximum power transfer theorem (Jacobi's law)

Questions and answers

What is the most a 12 V, 4 Ω source can deliver?

9 W into a 4 Ω load, at 50 % efficiency.

And into 8 Ω?

8 W at 66.7 % efficiency.

Do power systems match loads?

No: they aim for efficiency, so the load resistance is far above the source's.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.