FireCADCalc

Overhead Conductor Sag and Tension

Sag of an overhead conductor between level supports from its weight per metre, span and tension, by the parabola and the catenary, with conductor length.

Thermal power plantProcess steam and utilities

Inputs

Examples: 9.5 N/m, 250 m span, 15 kN3.2 N/m, 60 m, 2 kN16 N/m, 400 m, 25 kN

Results

Level supports, no wind or ice. Add wind and ice loads to the weight per metre as your line code requires.

Sag by the parabola w L² / (8 T)0.72000m
Sag by the catenary0.72014m
Conductor length in the span60.023m
Tension at the supports T + w S_c2.0023kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 9.5 N/m, 250 m span, 15 kN. The inputs, in the units selected above:

InputValue
Weight of the conductor per unit length9.5000 N/m
Span between supports250.00 m
Horizontal tension15.000 kN

Applying the formula below gives:

ResultValue
Sag by the parabola w L² / (8 T)4.9479 m
Sag by the catenary4.9505 m
Conductor length in the span250.26 m
Tension at the supports T + w S_c15.047 kN

Open this example in the calculator and change any input.

Formula

\(S = \frac{w L^2}{8 T}, \quad S_c = \frac{T}{w}\left(\cosh\frac{w L}{2 T} - 1\right), \quad l_c = \frac{2T}{w}\sinh\frac{wL}{2T}\)

Variables

Symbol Meaning SI unit
\(w\) Weight of the conductor per unit length N/m
\(L\) Span between supports m
\(T\) Horizontal tension N
\(S\) Sag by the parabola w L² / (8 T) m
\(S_c\) Sag by the catenary m
\(l_c\) Conductor length in the span m
\(T_{max}\) Tension at the supports T + w S_c N

Method and standards

Statics of a hanging conductor.

Where it is used

  • Distribution line stringing.
  • Clearance checks.
  • Electrical examinations.

Common mistakes

  • Using mass (kg/m) as weight.
  • Ignoring ice and wind.

Assumptions and limits

  • Supports at the same level.
  • A sag over a tenth of the span is flagged (the parabola is then inadequate); wL/(2T) above 5 is rejected as an unrealistically slack conductor.

References

  • Parabolic approximation and catenary of a uniform flexible conductor (textbook)

Questions and answers

What is the sag of a 250 m span, 9.5 N/m conductor at 15 kN?

4.95 m.

When is the parabola good enough?

When the sag is under about a tenth of the span.

How does temperature matter?

The conductor lengthens when hot, so sag rises and tension falls.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.