Worked example
Example: Illustrative: pegs 60 m apart, 1.524/1.187 midway, 1.402/1.071 near A. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Staff reading on A, level midway | 1.5240 m |
| Staff reading on B, level midway | 1.1870 m |
| Staff reading on A, level near A | 1.4020 m |
| Staff reading on B, level near A | 1.0710 m |
| Distance between the pegs | 60.000 m |
| Distance from the level to A in the second set-up | 3.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| True difference (midway) a₁ − b₁ | 337.00 mm |
| Apparent difference near A a₂ − b₂ | 331.00 mm |
| Collimation error over the peg distance | 6.0000 mm |
| Collimation error per 100 m | 10.000 mm |
| Correct reading on B for the second set-up | 1.0650 m |
| Line-of-sight inclination (+ up) | 20.626 ″ |
Open this example in the calculator and change any input.
Formula
\(\Delta h = a_1 - b_1, \quad e = (a_1 - b_1) - (a_2 - b_2), \quad b_{2,correct} = a_2 - \Delta h\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(a_1\) | Staff reading on A, level midway | m |
| \(b_1\) | Staff reading on B, level midway | m |
| \(a_2\) | Staff reading on A, level near A | m |
| \(b_2\) | Staff reading on B, level near A | m |
| \(L\) | Distance between the pegs | m |
| \(d_{near}\) | Distance from the level to A in the second set-up | m |
| \(\Delta h\) | True difference (midway) a₁ − b₁ | m |
| \(\Delta h_2\) | Apparent difference near A a₂ − b₂ | m |
| \(e\) | Collimation error over the peg distance | m |
| \(e/L\) | Collimation error per 100 m | m |
| \(b_{2,correct}\) | Correct reading on B for the second set-up | m |
| \(\alpha\) | Line-of-sight inclination (+ up) | rad |
Method and standards
Level collimation testing.
Where it is used
- Checking automatic and digital levels before use.
- Quality records for precise levelling.
Common mistakes
- Setting up the second station far from A.
- Not repeating readings to average out reading errors.
Assumptions and limits
- Curvature and refraction negligible over the peg distance.
References
- Two-peg collimation test
Questions and answers
Why do midway readings give the true difference?
Equal sight lengths make the collimation error identical on both staffs, so it cancels in the difference.
How often should a level be tested?
Before a major job, after any knock and regularly (monthly) on site; keep backsight and foresight lengths equal to limit the effect.
What do the defaults represent?
An illustrative test with pegs 60 m apart: midway 1.524/1.187 m, then 3 m from A 1.402/1.071 m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Uren and Price, Surveying for Engineers, 5th ed. (Palgrave Macmillan, 2010), ch. 3, Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012), ch. 5