FireCADCalc

Built-Up I-Section with Unequal Flanges: Elastic and Plastic Moduli

Area, centroid, second moments of area, elastic section moduli to each flange, plastic section modulus and radius of gyration of a welded monosymmetric I-section.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 300/250 flange welded girderCrane girder, wide top flangeHeavy bottom flange (PNA in flange)

Accepted: 20 to 2,000 mm
Accepted: 3 to 100 mm
Accepted: 50 to 5,000 mm
Accepted: 3 to 50 mm
Accepted: 20 to 2,000 mm
Accepted: 3 to 100 mm

Results

Parallel-axis theorem for the three plates; the plastic neutral axis splits the area in half, Z_p = Σ|A_iy_i| about it. Fillet welds are ignored. Unequal flanges suit crane girders (wider top flange for lateral loads) and composite beams (smaller top flange).

Area23,300mm²
Centroid above bottom54.056mm
Second moment of area, major axis19,961cm⁴
Elastic modulus to top fibre674.50cm³
Elastic modulus to bottom fibre3,692.7cm³
Plastic section modulus988.06cm³
Second moment of area, minor axis41,948cm⁴
Minor-axis radius of gyration134.18mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 300/250 flange welded girder. The inputs, in the units selected above:

InputValue
Top flange width300.00 mm
Top flange thickness20.000 mm
Web depth (clear)800.00 mm
Web thickness10.000 mm
Bottom flange width250.00 mm
Bottom flange thickness16.000 mm

Applying the formula below gives:

ResultValue
Area18,000 mm²
Centroid above bottom462.00 mm
Second moment of area, major axis206,332 cm⁴
Elastic modulus to top fibre5,516.9 cm³
Elastic modulus to bottom fibre4,466.1 cm³
Plastic section modulus5,592.0 cm³
Second moment of area, minor axis6,590.0 cm⁴
Minor-axis radius of gyration60.507 mm

Open this example in the calculator and change any input.

Formula

\(\bar y = \frac{\sum A_iy_i}{\sum A_i}, \quad I_x = \sum\left(I_i + A_i(y_i - \bar y)^2\right), \quad Z_p = \sum|A_i(y_i - y_p)|\)

Variables

Symbol Meaning SI unit
\(b_1\) Top flange width m
\(t_1\) Top flange thickness m
\(h_w\) Web depth (clear) m
\(t_w\) Web thickness m
\(b_2\) Bottom flange width m
\(t_2\) Bottom flange thickness m
\(A\) Area m²
\(\bar y\) Centroid above bottom m
\(I_x\) Second moment of area, major axis m⁴
\(Z_{top}\) Elastic modulus to top fibre m³
\(Z_{bot}\) Elastic modulus to bottom fibre m³
\(Z_p\) Plastic section modulus m³
\(I_y\) Second moment of area, minor axis m⁴
\(r_y\) Minor-axis radius of gyration m

Method and standards

Built-up section.

Where it is used

  • Plate girders and crane girders.
  • Checking fabricated beams and columns.

Common mistakes

  • Using the elastic centroid for plastic modulus.
  • Forgetting the web's own I in the sum.

Assumptions and limits

  • Plates only; welds and corner radii ignored.

References

  • Elastic and plastic properties of plate sections

Questions and answers

Why is the plastic neutral axis not at the centroid?

In an unsymmetric section the line that halves the area differs from the one that balances first moments.

What is the shape factor?

Z_p divided by the smaller elastic modulus: about 1.1–1.2 for I-sections, showing the reserve beyond first yield.

What do the defaults represent?

An illustrative welded girder: 300 × 20 mm top flange, 800 × 10 mm web, 250 × 16 mm bottom flange.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Salmon, Johnson and Malhas, Steel Structures: Design and Behavior, 5th ed. (Pearson, 2009)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.