Composite Steel–Concrete Beam: Plastic Neutral Axis and Moment

Plastic neutral axis and plastic moment of a steel I-beam with a concrete slab in full shear connection, with the axis in the slab or in the top flange.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 350 mm beam with 1.5 m slabNarrow slab, PNA in flangeHeavy beam, wide slab

Accepted: 100 to 100,000 mm²
Accepted: 100 to 2,000 mm
Accepted: 50 to 1,000 mm
Accepted: 4 to 80 mm
Accepted: 100 to 1,000 MPa
Accepted: 0.2 to 6 m
Accepted: 50 to 500 mm
Accepted: 5 to 80 MPa

Results

PNA in the slab: x = A_sf_y/(f_cd·b_eff), M_p = A_sf_y(t_s + h/2 − x/2) (symmetric steel section). Full shear connection is assumed: check the studs carry A_sf_y between zero and maximum moment.

Slab compressive force1,345.0kN
PNA depth below slab top52.745mm
PNA location (0 slab, 1 top flange)0
Plastic moment361.30kN·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 350 mm beam with 1.5 m slab. The inputs, in the units selected above:

InputValue
Steel beam area5,380.0 mm²
Steel beam depth350.00 mm
Top flange width140.00 mm
Top flange thickness12.200 mm
Steel design strength250.00 MPa
Effective slab width1.5000 m
Slab thickness120.00 mm
Concrete stress-block strength17.000 MPa

Applying the formula below gives:

ResultValue
Slab compressive force1,345.0 kN
PNA depth below slab top52.745 mm
PNA location (0 slab, 1 top flange)0
Plastic moment361.30 kN·m

Open this example in the calculator and change any input.

Formula

\(x = \frac{A_sf_y}{f_{cd}b_{eff}}, \quad M_p = A_sf_y\left(t_s + \frac{h}{2} - \frac{x}{2}\right)\ (x \le t_s)\)

Variables

Symbol Meaning SI unit
\(A_s\) Steel beam area m²
\(h\) Steel beam depth m
\(b_f\) Top flange width m
\(t_f\) Top flange thickness m
\(f_y\) Steel design strength Pa
\(b_{eff}\) Effective slab width m
\(t_s\) Slab thickness m
\(f_{cd}\) Concrete stress-block strength Pa
\(C_c\) Slab compressive force N
\(y_{pna}\) PNA depth below slab top m
\(\text{case}\) PNA location (0 slab, 1 top flange) -
\(M_p\) Plastic moment N·m

Method and standards

Composite section.

Where it is used

  • Floor beams in plant buildings and platforms.
  • Bridge stringers with concrete decks.

Common mistakes

  • Using gross slab width beyond the effective width.
  • Assuming full interaction with too few studs.

Assumptions and limits

  • Doubly symmetric steel section; full shear connection; concrete tension ignored.

References

  • Rigid-plastic analysis of composite sections

Questions and answers

Why is a composite beam so much stronger?

The slab carries the compression far above the steel, giving a long lever arm for the steel's tension.

What is full shear connection?

Enough shear studs to transfer the full compressive force between slab and steel, so the section reaches its plastic moment.

What do the defaults represent?

An illustrative 350 mm I-beam (5,380 mm², 140 × 12.2 mm flange) at 250 MPa under a 1.5 m × 120 mm slab with 17 MPa stress-block strength.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Johnson, Composite Structures of Steel and Concrete, 3rd ed. (Blackwell, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.