FireCADCalc

SPT N-Value Corrections: Energy and Overburden

SPT blow count corrected to 60 % hammer energy (N60) and to one atmosphere overburden ((N1)60) with borehole, sampler and rod corrections.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: N 18 at 8 m, safety hammerShallow N 10 at 2 m, automatic hammer

Results

Liao–Whitman C_N = √(p_a/σ′_v), capped at 1.7. Rod corrections: 0.75 for rods under 4 m, 0.85 for 4–6 m, 0.95 for 6–10 m, 1.0 beyond. Safety (rope-and-cathead) hammers deliver about 60 %, automatic hammers 70–90 %.

Energy-corrected N17.100
Overburden correction factor1.1254
Normalised N19.245

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: N 18 at 8 m, safety hammer. The inputs, in the units selected above:

InputValue
Field blow count18.000 -
Hammer energy ratio60.000 %
Borehole diameter correction1.0000 -
Sampler correction1.0000 -
Rod length correction0.95000 -
Effective overburden stress80.000 kPa

Applying the formula below gives:

ResultValue
Energy-corrected N17.100
Overburden correction factor1.1254
Normalised N19.245

Open this example in the calculator and change any input.

Formula

\(N_{60} = N\frac{E_r}{0.6}C_BC_SC_R, \quad (N_1)_{60} = C_NN_{60}, \quad C_N = \sqrt{\frac{p_a}{\sigma'_v}} \le 1.7\)

Variables

Symbol Meaning SI unit
\(N\) Field blow count -
\(E_r\) Hammer energy ratio -
\(C_B\) Borehole diameter correction -
\(C_S\) Sampler correction -
\(C_R\) Rod length correction -
\(\sigma'_v\) Effective overburden stress Pa
\(N_{60}\) Energy-corrected N -
\(C_N\) Overburden correction factor -
\((N_1)_{60}\) Normalised N -
\(p_a\) Atmospheric pressure, 101 325 Pa

Method and standards

Skempton and Liao–Whitman.

Where it is used

  • Site investigation reports.
  • Liquefaction screening.

Common mistakes

  • Using total instead of effective stress.
  • Applying corrections twice.

Assumptions and limits

  • Sands; standard SPT procedure.
  • p_a is taken as one standard atmosphere, 101.325 kPa. Many texts write Liao–Whitman with p_a = 100 kPa (or 1 tsf); that gives C_N about 0.66 % lower.

References

  • Skempton (1986) energy and equipment corrections; Liao and Whitman (1986) overburden correction (Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011), ch. 2)

Questions and answers

Why correct N at all?

Different hammers deliver different energy, and the same sand gives higher N under more overburden; corrections make values comparable.

Where is (N₁)₆₀ used?

In correlations for friction angle, relative density and liquefaction resistance.

What do the defaults represent?

A blow count of 18 at about 8 m depth with a safety hammer.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.