Worked example
Example: Sand 30°, 4 m wall, 10 kPa surcharge. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bulk density of the soil | 1,800.0 kg/m³ |
| Angle of internal friction | 30.000 ° |
| Cohesion | 0 kPa |
| Height of the wall | 4.0000 m |
| Uniform surcharge on the backfill | 10.000 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Active earth pressure coefficient | 0.33333 |
| Passive earth pressure coefficient | 3.0000 |
| Active pressure at the base | 26.869 kPa |
| Depth of the tension crack | 0 m |
| Active thrust per metre of wall | 60.405 kN/m |
| Height of the active thrust above the base | 1.4805 m |
| Passive resistance over depth H, no surcharge (per metre) | 423.65 kN/m |
Open this example in the calculator and change any input.
Formula
\(K_a = \tan^2\left(45° - \frac{\varphi}{2}\right), \quad K_p = \tan^2\left(45° + \frac{\varphi}{2}\right)\)
\(\sigma_a(z) = K_a(\rho g z + q) - 2c\sqrt{K_a}, \quad z_c: \sigma_a(z_c) = 0\)
\(P_a = \int_{z_c}^{H} \sigma_a\, dz, \quad P_p = \tfrac12 K_p \rho g H^2 + 2c\sqrt{K_p} H\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Bulk density of the soil | kg/m³ |
| \(\varphi\) | Angle of internal friction | rad |
| \(c\) | Cohesion | Pa |
| \(H\) | Height of the wall | m |
| \(q\) | Uniform surcharge on the backfill | Pa |
| \(K_a\) | Active earth pressure coefficient | - |
| \(K_p\) | Passive earth pressure coefficient | - |
| \(\sigma_a\) | Active pressure at the base | Pa |
| \(z_c\) | Depth of the tension crack | m |
| \(P_a\) | Active thrust per metre of wall | N/m |
| \(\bar y\) | Height of the active thrust above the base | m |
| \(P_p\) | Passive resistance over depth H, no surcharge (per metre) | N/m |
| \(g\) | Standard gravity | m/s² |
| \(\sigma_a(z)\) | Active pressure at depth z | Pa |
Method and standards
Rankine's limiting stress states for a smooth vertical wall and level backfill, with Bell's cohesion term; the active thrust integrates only the compressive part of the pressure.
Where it is used
- Retaining walls, basement walls and pit walls.
- Temporary excavation shoring.
- Coal and ash pit walls.
Common mistakes
- Leaving out water pressure behind an undrained wall.
- Counting tension in clay as pressure.
- Relying on full passive pressure with little movement.
Assumptions and limits
- Smooth vertical wall; level, drained backfill.
- No wall friction, seismic or compaction loads.
References
- W.J.M. Rankine (1857); Bell (1915) for cohesive soil
Questions and answers
What thrust does 4 m of sand at 30° put on a wall?
Ka = 1/3; with a 10 kPa surcharge the thrust is 60.4 kN per metre of wall, acting 1.48 m above the base.
How does cohesion change it?
It reduces the pressure near the top; with 15 kPa cohesion, 20° friction, 1800 kg/m³ and no surcharge the top 2.4 m is in tension (1.9 m with a 10 kPa surcharge) and is taken as carrying no pressure.
What is passive pressure?
The resistance of soil pushed by the wall, such as in front of the toe; Kp = 3 for 30°, but it needs large movement to develop. The surcharge on the backfill does not act in front of the wall, so it is left out of P_p.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.