FireCADCalc

Rankine Active and Passive Earth Pressure on a Wall

Active and passive earth pressure coefficients, pressure at the base and resultant thrust per metre of a vertical wall with level backfill by Rankine's theory.

Inputs

Examples: Sand 30°, 4 m wall, 10 kPa surchargeClayey soil 20°, c 15 kPa, 6 m wallDense sand 35°, 3 m wall

Results

Smooth vertical wall, level drained backfill, no water pressure; tension in cohesive soil is ignored down to the crack depth. Add water pressure where the backfill can be wet.

Active earth pressure coefficient0.27099
Passive earth pressure coefficient3.6902
Active pressure at the base15.945kPa
Depth of the tension crack0m
Active thrust per metre of wall23.918kN/m
Height of the active thrust above the base1.0000m
Passive resistance over depth H, no surcharge (per metre)325.69kN/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sand 30°, 4 m wall, 10 kPa surcharge. The inputs, in the units selected above:

InputValue
Bulk density of the soil1,800.0 kg/m³
Angle of internal friction30.000 °
Cohesion0 kPa
Height of the wall4.0000 m
Uniform surcharge on the backfill10.000 kPa

Applying the formula below gives:

ResultValue
Active earth pressure coefficient0.33333
Passive earth pressure coefficient3.0000
Active pressure at the base26.869 kPa
Depth of the tension crack0 m
Active thrust per metre of wall60.405 kN/m
Height of the active thrust above the base1.4805 m
Passive resistance over depth H, no surcharge (per metre)423.65 kN/m

Open this example in the calculator and change any input.

Formula

\(K_a = \tan^2\left(45° - \frac{\varphi}{2}\right), \quad K_p = \tan^2\left(45° + \frac{\varphi}{2}\right)\)

\(\sigma_a(z) = K_a(\rho g z + q) - 2c\sqrt{K_a}, \quad z_c: \sigma_a(z_c) = 0\)

\(P_a = \int_{z_c}^{H} \sigma_a\, dz, \quad P_p = \tfrac12 K_p \rho g H^2 + 2c\sqrt{K_p} H\)

Variables

Symbol Meaning SI unit
\(\rho\) Bulk density of the soil kg/m³
\(\varphi\) Angle of internal friction rad
\(c\) Cohesion Pa
\(H\) Height of the wall m
\(q\) Uniform surcharge on the backfill Pa
\(K_a\) Active earth pressure coefficient -
\(K_p\) Passive earth pressure coefficient -
\(\sigma_a\) Active pressure at the base Pa
\(z_c\) Depth of the tension crack m
\(P_a\) Active thrust per metre of wall N/m
\(\bar y\) Height of the active thrust above the base m
\(P_p\) Passive resistance over depth H, no surcharge (per metre) N/m
\(g\) Standard gravity m/s²
\(\sigma_a(z)\) Active pressure at depth z Pa

Method and standards

Rankine's limiting stress states for a smooth vertical wall and level backfill, with Bell's cohesion term; the active thrust integrates only the compressive part of the pressure.

Where it is used

  • Retaining walls, basement walls and pit walls.
  • Temporary excavation shoring.
  • Coal and ash pit walls.

Common mistakes

  • Leaving out water pressure behind an undrained wall.
  • Counting tension in clay as pressure.
  • Relying on full passive pressure with little movement.

Assumptions and limits

  • Smooth vertical wall; level, drained backfill.
  • No wall friction, seismic or compaction loads.

References

  • W.J.M. Rankine (1857); Bell (1915) for cohesive soil

Questions and answers

What thrust does 4 m of sand at 30° put on a wall?

Ka = 1/3; with a 10 kPa surcharge the thrust is 60.4 kN per metre of wall, acting 1.48 m above the base.

How does cohesion change it?

It reduces the pressure near the top; with 15 kPa cohesion, 20° friction, 1800 kg/m³ and no surcharge the top 2.4 m is in tension (1.9 m with a 10 kPa surcharge) and is taken as carrying no pressure.

What is passive pressure?

The resistance of soil pushed by the wall, such as in front of the toe; Kp = 3 for 30°, but it needs large movement to develop. The surcharge on the backfill does not act in front of the wall, so it is left out of P_p.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.