FireCADCalc

Active Earth Pressure with Surcharge and Water Table

Rankine active pressure on a wall with surcharge and a water table in the backfill: base pressure, soil and water thrust and line of action.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 6 m wall, water 3 m down, φ′ 30°, 10 kPa4 m wall, dry backfill, 20 kPa

Results

Rankine: smooth vertical wall, horizontal backfill, cohesionless soil. Below the water table soil pressure uses the submerged weight and water pressure is added in full: drains that keep the backfill dry halve the thrust in many cases.

Active coefficient0.30726
Total lateral pressure at the base27.653kPa
Soil thrust (incl. surcharge)67.597kN/m
Water thrust0kN/m
Total thrust per metre67.597kN/m
Height of the resultant above the base1.5758m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 6 m wall, water 3 m down, φ′ 30°, 10 kPa. The inputs, in the units selected above:

InputValue
Wall height6.0000 m
Depth of water table below the top3.0000 m
Effective friction angle30.000 °
Unit weight above the water table18.000 kN/m³
Saturated unit weight20.000 kN/m³
Uniform surcharge10.000 kPa

Applying the formula below gives:

ResultValue
Active coefficient0.33333
Total lateral pressure at the base60.953 kPa
Soil thrust (incl. surcharge)116.28 kN/m
Water thrust44.145 kN/m
Total thrust per metre160.43 kN/m
Height of the resultant above the base1.9225 m

Open this example in the calculator and change any input.

Formula

\(\sigma_h' = K_a(q + \gamma d_1 + \gamma'z_2), \quad u = \gamma_wz_2, \quad K_a = \frac{1 - \sin\phi'}{1 + \sin\phi'}\)

Variables

Symbol Meaning SI unit
\(H\) Wall height m
\(h_w\) Depth of water table below the top m
\(\phi'\) Effective friction angle rad
\(\gamma\) Unit weight above the water table N/m³
\(\gamma_{sat}\) Saturated unit weight N/m³
\(q\) Uniform surcharge Pa
\(K_a\) Active coefficient -
\(p_{base}\) Total lateral pressure at the base Pa
\(P_s\) Soil thrust (incl. surcharge) N/m
\(P_w\) Water thrust N/m
\(P\) Total thrust per metre N/m
\(\bar z\) Height of the resultant above the base m

Method and standards

Rankine with effective stress.

Where it is used

  • Retaining walls, basements and pits.
  • Cooling tower basins and sumps.

Common mistakes

  • Using total unit weight below the water table.
  • Forgetting the water pressure.

Assumptions and limits

  • Cohesionless backfill (no c′ term, no tension crack); static water; unit weight of water γ_w = 9.81 kN/m³.
  • A saturated unit weight not above the moist one is flagged.

References

  • Rankine active pressure with effective stresses (Das, Principles of Geotechnical Engineering, 7th ed. (Cengage, 2010), ch. 13)

Questions and answers

Why does water raise the thrust so much?

Water pushes with K = 1, while soil pushes with K_a ≈ 0.33; a saturated backfill nearly doubles the load.

How is surcharge included?

As a uniform extra vertical stress q, giving a rectangular K_aq block over the full height.

What do the defaults represent?

A 6 m wall with the water table 3 m down, φ′ = 30° and a 10 kPa surcharge.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.