Worked example
Example: 6 m wall, water 3 m down, φ′ 30°, 10 kPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wall height | 6.0000 m |
| Depth of water table below the top | 3.0000 m |
| Effective friction angle | 30.000 ° |
| Unit weight above the water table | 18.000 kN/m³ |
| Saturated unit weight | 20.000 kN/m³ |
| Uniform surcharge | 10.000 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Active coefficient | 0.33333 |
| Total lateral pressure at the base | 60.953 kPa |
| Soil thrust (incl. surcharge) | 116.28 kN/m |
| Water thrust | 44.145 kN/m |
| Total thrust per metre | 160.43 kN/m |
| Height of the resultant above the base | 1.9225 m |
Open this example in the calculator and change any input.
Formula
\(\sigma_h' = K_a(q + \gamma d_1 + \gamma'z_2), \quad u = \gamma_wz_2, \quad K_a = \frac{1 - \sin\phi'}{1 + \sin\phi'}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Wall height | m |
| \(h_w\) | Depth of water table below the top | m |
| \(\phi'\) | Effective friction angle | rad |
| \(\gamma\) | Unit weight above the water table | N/m³ |
| \(\gamma_{sat}\) | Saturated unit weight | N/m³ |
| \(q\) | Uniform surcharge | Pa |
| \(K_a\) | Active coefficient | - |
| \(p_{base}\) | Total lateral pressure at the base | Pa |
| \(P_s\) | Soil thrust (incl. surcharge) | N/m |
| \(P_w\) | Water thrust | N/m |
| \(P\) | Total thrust per metre | N/m |
| \(\bar z\) | Height of the resultant above the base | m |
Method and standards
Rankine with effective stress.
Where it is used
- Retaining walls, basements and pits.
- Cooling tower basins and sumps.
Common mistakes
- Using total unit weight below the water table.
- Forgetting the water pressure.
Assumptions and limits
- Cohesionless backfill (no c′ term, no tension crack); static water; unit weight of water γ_w = 9.81 kN/m³.
- A saturated unit weight not above the moist one is flagged.
References
- Rankine active pressure with effective stresses (Das, Principles of Geotechnical Engineering, 7th ed. (Cengage, 2010), ch. 13)
Questions and answers
Why does water raise the thrust so much?
Water pushes with K = 1, while soil pushes with K_a ≈ 0.33; a saturated backfill nearly doubles the load.
How is surcharge included?
As a uniform extra vertical stress q, giving a rectangular K_aq block over the full height.
What do the defaults represent?
A 6 m wall with the water table 3 m down, φ′ = 30° and a 10 kPa surcharge.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.