FireCADCalc

Seepage Flow by Darcy's Law

Seepage flow, discharge velocity and seepage velocity through a soil from permeability, hydraulic gradient (head loss over length), area and porosity.

Inputs

Examples: Sand bundClay linerGravel

Results

Hydraulic gradient Δh/L0.005000
Discharge (Darcy) velocity k i5.0000e-05m/s
Seepage velocity v/n1.6667e-04m/s
Seepage flow86.400m³/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sand bund. The inputs, in the units selected above:

InputValue
Coefficient of permeability1.0000e-05 m/s
Head loss3.0000 m
Flow length15.000 m
Flow cross-section50.000 m²
Porosity35.000 %

Applying the formula below gives:

ResultValue
Hydraulic gradient Δh/L0.20000
Discharge (Darcy) velocity k i2.0000e-06 m/s
Seepage velocity v/n5.7143e-06 m/s
Seepage flow8.6400 m³/d

Open this example in the calculator and change any input.

Formula

\(i = \frac{\Delta h}{L}, \quad v = k i, \quad v_s = \frac{v}{n}, \quad Q = k i A\)

Variables

Symbol Meaning SI unit
\(k\) Coefficient of permeability m/s
\(\Delta h\) Head loss m
\(L\) Flow length m
\(A\) Flow cross-section m²
\(n\) Porosity -
\(i\) Hydraulic gradient Δh/L -
\(v\) Discharge (Darcy) velocity k i m/s
\(v_s\) Seepage velocity v/n m/s
\(Q\) Seepage flow m³/s

Method and standards

Darcy's law.

Where it is used

  • Dewatering and seepage estimates.
  • Contaminant travel time.

Common mistakes

  • Using seepage velocity for flow.
  • Gross area vs pore area confusion.

Assumptions and limits

  • Laminar, saturated, homogeneous.
  • The seepage velocity uses the porosity entered. For contaminant travel time use the effective (connected) porosity, usually smaller than the total, which gives a faster travel.

References

  • Darcy's law Q = k i A

Questions and answers

k 1e-5 m/s, 3 m over 15 m, 50 m²?

Gradient 0.2, flow 8.6 m³/day.

Why is seepage velocity higher?

Water moves only through the pores.

Turbulent flow?

Darcy's law needs laminar flow; true for most soils.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.