Worked example
Example: Sand bund. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Coefficient of permeability | 1.0000e-05 m/s |
| Head loss | 3.0000 m |
| Flow length | 15.000 m |
| Flow cross-section | 50.000 m² |
| Porosity | 35.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic gradient Δh/L | 0.20000 |
| Discharge (Darcy) velocity k i | 2.0000e-06 m/s |
| Seepage velocity v/n | 5.7143e-06 m/s |
| Seepage flow | 8.6400 m³/d |
Open this example in the calculator and change any input.
Formula
\(i = \frac{\Delta h}{L}, \quad v = k i, \quad v_s = \frac{v}{n}, \quad Q = k i A\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | Coefficient of permeability | m/s |
| \(\Delta h\) | Head loss | m |
| \(L\) | Flow length | m |
| \(A\) | Flow cross-section | m² |
| \(n\) | Porosity | - |
| \(i\) | Hydraulic gradient Δh/L | - |
| \(v\) | Discharge (Darcy) velocity k i | m/s |
| \(v_s\) | Seepage velocity v/n | m/s |
| \(Q\) | Seepage flow | m³/s |
Method and standards
Darcy's law.
Where it is used
- Dewatering and seepage estimates.
- Contaminant travel time.
Common mistakes
- Using seepage velocity for flow.
- Gross area vs pore area confusion.
Assumptions and limits
- Laminar, saturated, homogeneous.
- The seepage velocity uses the porosity entered. For contaminant travel time use the effective (connected) porosity, usually smaller than the total, which gives a faster travel.
References
- Darcy's law Q = k i A
Questions and answers
k 1e-5 m/s, 3 m over 15 m, 50 m²?
Gradient 0.2, flow 8.6 m³/day.
Why is seepage velocity higher?
Water moves only through the pores.
Turbulent flow?
Darcy's law needs laminar flow; true for most soils.