FireCADCalc

Critical Hydraulic Gradient, Exit Gradient Safety and Heave

Critical hydraulic gradient for a quick condition, the safety factor against piping at an exit gradient and the factor against heave of a soil plug.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative sand, sheet pile 4 mLoose silty sand, high gradientDense gravel, deep cut-off

Accepted: 2.4 to 3
Accepted: 0.2 to 2
Accepted: 0.01 to 2
Accepted: 0.1 to 30 m
Accepted: 0.01 to 50 m

Results

i_c = (G_s − 1)/(1 + e) = γ′/γ_w, about 1 for most soils. Factor against piping i_c/i_e (often 3–4 required); Terzaghi's heave check of a soil prism D wide by D deep beside a sheet pile compares its submerged weight with the uplift from the average excess head: FS = γ′D/(γ_wh_a).

Submerged unit weight11.908kN/m³
Critical gradient1.2143
Safety factor against piping6.0714
Safety factor against heave (Terzaghi plug)3.6429

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative sand, sheet pile 4 m. The inputs, in the units selected above:

InputValue
Specific gravity of solids2.6500 -
Void ratio0.65000 -
Exit hydraulic gradient0.35000 -
Embedment depth of the plug (sheet pile)4.0000 m
Average excess head at the plug base2.5000 m

Applying the formula below gives:

ResultValue
Submerged unit weight9.8066 kN/m³
Critical gradient1.0000
Safety factor against piping2.8571
Safety factor against heave (Terzaghi plug)1.6000

Open this example in the calculator and change any input.

Formula

\(i_c = \frac{G_s - 1}{1 + e}, \quad FS_p = \frac{i_c}{i_e}, \quad FS_h = \frac{\gamma'D}{\gamma_wh_a}\)

Variables

Symbol Meaning SI unit
\(G_s\) Specific gravity of solids -
\(e\) Void ratio -
\(i_e\) Exit hydraulic gradient -
\(D\) Embedment depth of the plug (sheet pile) m
\(h_a\) Average excess head at the plug base m
\(\gamma'\) Submerged unit weight N/m³
\(i_c\) Critical gradient -
\(FS_p\) Safety factor against piping -
\(FS_h\) Safety factor against heave (Terzaghi plug) -

Method and standards

Seepage safety.

Where it is used

  • Cofferdams and excavations below groundwater.
  • Weir and dam foundation checks.

Common mistakes

  • Using bulk instead of submerged unit weight.
  • Taking the average gradient instead of the exit gradient.

Assumptions and limits

  • Homogeneous soil; steady seepage.

References

  • Critical gradient and Terzaghi heave

Questions and answers

What is a quick condition?

Upward seepage force equals the soil's submerged weight, so effective stress vanishes and sand behaves like a liquid.

Where does the exit gradient come from?

From a flow net or seepage analysis at the downstream surface or excavation base.

What do the defaults represent?

An illustrative sand with G_s 2.65 and e 0.65, exit gradient 0.35, sheet pile embedded 4 m with 2.5 m average excess head at the plug base.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Craig, Craig's Soil Mechanics, 8th ed. (Spon, 2012), Das and Sobhan, Principles of Geotechnical Engineering, 8th ed. (Cengage, 2014)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.