FireCADCalc

Modulus of Subgrade Reaction for a Footing (Terzaghi and Vesić)

Modulus of subgrade reaction of a footing scaled from a 0.3 m plate load test (Terzaghi) and estimated from soil modulus and footing stiffness (Vesić).

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 2 x 3 m footing on sandRaft 12 x 20 m on claySquare 1.5 m footing on sand

Accepted: 0.1 to 500 MN/m³
Accepted: 0.3 to 50 m
Accepted: 0.3 to 100 m
Accepted: 0.1 to 5,000 MPa
Accepted: 0 to 0.5
Accepted: 1 to 250 GPa
Accepted: 100 to 5,000 mm

Results

Terzaghi: sand k = k₁[(B + 0.3)/(2B)]², clay k = k₁(0.3/B)(L/B + 0.5)/(1.5L/B), B in metres. Vesić: k_sB = 0.65(E_sB⁴/E_fI_f)^(1/12)·E_s/(1 − ν²). Subgrade modulus is not a soil property: it depends on footing size, shape, stiffness and load level, so bracket results in design.

Terzaghi scaled modulus13.225MN/m³
Vesić modulus10.167MN/m³
Vesić spring per unit length of beam20.335MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 x 3 m footing on sand. The inputs, in the units selected above:

InputValue
Soil type for plate scalingSand (granular)
Plate (0.3 m) subgrade modulus40.000 MN/m³
Footing width2.0000 m
Footing length3.0000 m
Soil elastic modulus30.000 MPa
Soil Poisson's ratio0.30000 -
Footing elastic modulus25.000 GPa
Footing thickness600.00 mm

Applying the formula below gives:

ResultValue
Terzaghi scaled modulus13.225 MN/m³
Vesić modulus10.167 MN/m³
Vesić spring per unit length of beam20.335 MPa

Open this example in the calculator and change any input.

Formula

\(k_{sand} = k_1\left(\frac{B + 0.3}{2B}\right)^2, \quad k_{clay} = k_1\frac{0.3}{B}\frac{L/B + 0.5}{1.5L/B}, \quad k_sB = 0.65\sqrt[12]{\frac{E_sB^4}{E_fI_f}}\frac{E_s}{1 - \nu^2}\)

Variables

Symbol Meaning SI unit
\(\text{soil}\) Soil type for plate scaling -
\(k_1\) Plate (0.3 m) subgrade modulus N/m³
\(B\) Footing width m
\(L\) Footing length m
\(E_s\) Soil elastic modulus Pa
\(\nu\) Soil Poisson's ratio -
\(E_f\) Footing elastic modulus Pa
\(t\) Footing thickness m
\(k_T\) Terzaghi scaled modulus N/m³
\(k_V\) Vesić modulus N/m³
\(k_sB\) Vesić spring per unit length of beam Pa

Method and standards

Subgrade modulus.

Where it is used

  • Raft and grade beam analysis on springs.
  • Machine and tank foundation models.

Common mistakes

  • Using the plate value directly for a large raft.
  • Treating k as a fixed soil constant.

Assumptions and limits

  • Linear elastic soil; footing in full contact.

References

  • Terzaghi plate scaling; Vesić beam-on-elastic-solid

Questions and answers

Why does k fall as footings get wider?

A wider footing stresses soil to a greater depth, so it settles more under the same pressure.

Which value should I use?

Both are estimates; run raft and beam analyses with a range, often half to twice the estimate.

What do the defaults represent?

An illustrative 2 m × 3 m, 600 mm concrete footing on sand with a plate test k₁ of 40 MN/m³ and E_s 30 MPa.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Terzaghi, Evaluation of coefficients of subgrade reaction, Géotechnique 5(4), 297 (1955), Vesić, Bending of beams resting on isotropic elastic solid, J. Eng. Mech. Div. ASCE 87(2), 35 (1961), Bowles, Foundation Analysis and Design, 5th ed. (McGraw-Hill, 1996)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.