Worked example
Example: 4 × 6 m panel at 10 kN/m². The inputs, in the units selected above:
| Input | Value |
|---|---|
| Slab load (dead + imposed) | 10.000 kPa |
| Short span | 4.0000 m |
| Long span | 6.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total load on each short-span beam | 40.000 kN |
| Total load on each long-span beam | 80.000 kN |
| Equivalent UDL for moment, short beam | 13.333 kN/m |
| Equivalent UDL for moment, long beam | 17.037 kN/m |
| Equivalent UDL for shear, short beam | 10.000 kN/m |
| Equivalent UDL for shear, long beam | 13.333 kN/m |
Open this example in the calculator and change any input.
Formula
\(W_s = \frac{w l_x^2}{4}, \quad W_l = \frac{w l_x (2l_y - l_x)}{4}\)
\(w_{e,s} = \frac{wl_x}{3}, \quad w_{e,l} = \frac{wl_x}{6}\left[3 - \left(\frac{l_x}{l_y}\right)^2\right] \quad \text{(moment)}\)
\(w_{v,s} = \frac{wl_x}{4}, \quad w_{v,l} = \frac{wl_x}{4}\left(2 - \frac{l_x}{l_y}\right) \quad \text{(shear)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(w\) | Slab load (dead + imposed) | Pa |
| \(l_x\) | Short span | m |
| \(l_y\) | Long span | m |
| \(W_s\) | Total load on each short-span beam | N |
| \(W_l\) | Total load on each long-span beam | N |
| \(w_{e,s}\) | Equivalent UDL for moment, short beam | N/m |
| \(w_{e,l}\) | Equivalent UDL for moment, long beam | N/m |
| \(w_{v,s}\) | Equivalent UDL for shear, short beam | N/m |
| \(w_{v,l}\) | Equivalent UDL for shear, long beam | N/m |
Method and standards
Tributary areas.
Where it is used
- Beam design in framed buildings.
- Platform and floor checks.
Common mistakes
- Using the moment equivalent for shear.
- Adding beam self weight twice.
Assumptions and limits
- Uniform load; 45° division of a two-way panel.
- For l_y > 2 l_x the slab is one-way: the page warns, and the 45° split then overstates the short-span beam load.
References
- Yield-line (45°) tributary division and equivalent uniform loads (Punmia, Reinforced Concrete Structures)
Questions and answers
Why do the short beams get triangles?
Load flows to the nearest support; the 45° lines from the corners meet sooner along the short side.
When is a slab one-way?
When the long span exceeds about twice the short span; then nearly all load goes to the long beams.
What do the defaults represent?
A 4 × 6 m panel carrying 10 kN/m².
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.