FireCADCalc

Catalyst Effectiveness Factor from the Thiele Modulus

Thiele modulus and internal effectiveness factor of a porous catalyst pellet (sphere, cylinder-approx. or slab) for a first-order reaction, and the observed rate.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 4 mm sphere, k 5 /s, De 1e-7Slab 2 mm, slow reaction

Results

Isothermal pellet and first-order kinetics; a slab reacting from both faces has L_c equal to half its thickness, a sphere d/6. For φ above about 3, η ≈ 1/φ: strong pore-diffusion limitation.

Characteristic length V/S1.0000mm
Generalised Thiele modulus0.70711
Effectiveness factor86.106%
Observed rate constant0.043053Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 4 mm sphere, k 5 /s, De 1e-7. The inputs, in the units selected above:

InputValue
Pellet shapeSphere
Sphere diameter or slab thickness4.0000 mm
First-order rate constant per pellet volume5.0000 Hz
Effective diffusivity in the pellet1.0000e-07 m²/s

Applying the formula below gives:

ResultValue
Characteristic length V/S0.66667 mm
Generalised Thiele modulus4.7140
Effectiveness factor19.713 %
Observed rate constant0.98566 Hz

Open this example in the calculator and change any input.

Formula

\(\phi = L_c\sqrt{\frac{k_v}{D_e}}, \ L_c = \frac{V_p}{S_p}\ (\text{sphere } d_p/6,\ \text{slab, both faces } d_p/2), \quad \eta_{sphere} = \frac{1}{3\phi^2}\left(\frac{3\phi}{\tanh3\phi} - 1\right), \quad \eta_{slab} = \frac{\tanh\phi}{\phi}\)

Variables

Symbol Meaning SI unit
\(\text{shape}\) Pellet shape -
\(d_p\) Sphere diameter or slab thickness m
\(k_v\) First-order rate constant per pellet volume 1/s
\(D_e\) Effective diffusivity in the pellet m²/s
\(L_c\) Characteristic length V/S m
\(\phi\) Generalised Thiele modulus -
\(\eta\) Effectiveness factor -
\(\eta k_v\) Observed rate constant 1/s

Method and standards

Generalised Thiele modulus.

Where it is used

  • Catalyst size and shape selection.
  • Diagnosing pore-diffusion limits.

Common mistakes

  • Using bulk diffusivity instead of effective.
  • Rate constant per mass instead of per pellet volume.

Assumptions and limits

  • Isothermal; first order.

References

  • Levenspiel
  • Chemical Reaction Engineering
  • 3rd ed. (Wiley, 1999)
  • ch. 18 (effectiveness factor and generalised Thiele modulus)
  • Fogler
  • Elements of Chemical Reaction Engineering
  • 5th ed.
  • ch. 15

Questions and answers

What does an effectiveness factor of 0.3 mean?

The pellet reacts at 30 % of the rate it would if the whole interior saw the surface concentration; the core is starved by slow diffusion.

How can I raise it?

Smaller pellets, more porous supports or egg-shell catalysts with the active metal near the surface.

What do the defaults represent?

A 4 mm spherical pellet with a fast first-order reaction.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.