FireCADCalc

Plug Flow Reactor (PFR) Volume for a Conversion

Space time and volume of a plug flow (tubular) reactor for a target conversion with first- or second-order kinetics, and the CSTR volume for comparison.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: First order, 80 %Second order, 90 %

Results

Constant density, isothermal, no axial mixing.

Space time180.00min
Reactor volume15.000m³
CSTR volume for the same duty150.00m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: First order, 80 %. The inputs, in the units selected above:

InputValue
Feed volumetric flow10.000 m³/h
Target conversion80.000 %
Reaction orderFirst order
Rate constant k·C_A0^(n−1)0.20000 1/min

Applying the formula below gives:

ResultValue
Space time8.0472 min
Reactor volume1.3412 m³
CSTR volume for the same duty3.3333 m³

Open this example in the calculator and change any input.

Formula

\(\tau = -\frac{\ln(1 - X)}{k} \ (n = 1), \quad \tau = \frac{X}{k C_{A0}(1 - X)} \ (n = 2)\)

Variables

Symbol Meaning SI unit
\(\dot V\) Feed volumetric flow m³/s
\(X\) Target conversion -
\(n\) Reaction order -
\(k'\) Rate constant k·C_A0^(n−1) 1/s
\(\tau\) Space time s
\(V\) Reactor volume m³
\(V_{CSTR}\) CSTR volume for the same duty m³

Method and standards

Integrated design equation.

Where it is used

  • Tubular reactors and long pipelines.
  • Comparing reactor types.

Common mistakes

  • Using it for gas reactions with mole change.
  • Wrong rate units.

Assumptions and limits

  • Isothermal, constant density.

References

  • PFR design equation V = F_A0 ∫dX/(−r_A) integrated for n = 1
  • 2 (Fogler; Levenspiel)

Questions and answers

10 m³/h, 80 %, first order k 0.2 /min?

τ = 8.05 min: 1.34 m³, against 3.33 m³ as a CSTR.

Why is a PFR smaller?

Concentration falls gradually along it, keeping the rate high upstream.

Real tubular reactors?

Some back-mixing; use dispersion models for long, slow ones.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.