FireCADCalc

CSTR Volume for a Conversion (First or Second Order)

Residence time and volume of a continuous stirred tank reactor (CSTR) for a target conversion with first- or second-order kinetics.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: First order, 80 %Second order, 90 %

For first order k itself; for second order k × C_A0.

Results

Constant density, perfect mixing, isothermal. A CSTR works at the outlet concentration, so it needs more volume than a plug flow reactor.

Residence time1,800.0min
Reactor volume150.00m³
Damköhler number k'τ90.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: First order, 80 %. The inputs, in the units selected above:

InputValue
Feed volumetric flow10.000 m³/h
Target conversion80.000 %
Reaction orderFirst order
Rate constant k·C_A0^(n−1)0.20000 1/min

Applying the formula below gives:

ResultValue
Residence time20.000 min
Reactor volume3.3333 m³
Damköhler number k'τ4.0000

Open this example in the calculator and change any input.

Formula

\(\tau = \frac{X}{k(1 - X)} \ (n = 1), \quad \tau = \frac{X}{k C_{A0}(1 - X)^2} \ (n = 2), \quad V = \dot V \tau\)

Variables

Symbol Meaning SI unit
\(\dot V\) Feed volumetric flow m³/s
\(X\) Target conversion -
\(n\) Reaction order -
\(k'\) Rate constant k·C_A0^(n−1) 1/s
\(\tau\) Residence time s
\(V\) Reactor volume m³
\(Da\) Damköhler number k'τ -

Method and standards

CSTR design equation.

Where it is used

  • Continuous reactors and neutralisers.
  • Effluent treatment tanks.

Common mistakes

  • Using inlet concentration for the rate.
  • Volume without headspace.

Assumptions and limits

  • Isothermal, constant density.

References

  • CSTR design equation V = F_A0 X/(−r_A) at outlet conditions (Fogler; Levenspiel)

Questions and answers

10 m³/h, 80 %, first order k 0.2 /min?

τ = 20 min: 3.33 m³.

Why bigger than a PFR?

All the tank runs at the low outlet concentration.

Several tanks?

See CSTRs in series: they approach plug flow.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.