FireCADCalc

Vapour Pressure by Riedel and Ambrose–Walton

Vapour pressure of an organic liquid from its normal boiling point and critical constants by the Riedel method, and from the acentric factor by Ambrose–Walton.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Chlorobenzene 500 K (Perry's example: 7.74 bar Riedel)Chlorobenzene 350 Kn-Hexane 340 K

Results

Perry's: about 1 % above the normal boiling point, 5–30 % near the triple point. Estimate for design; use measured data where they exist.

Vapour pressure, Riedel7.7352bar
Vapour pressure, Ambrose–Walton7.6671bar
Reduced temperature0.79070

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Chlorobenzene 500 K (Perry's example: 7.74 bar Riedel). The inputs, in the units selected above:

InputValue
Temperature226.85 °C
Normal boiling point131.72 °C
Critical temperature359.20 °C
Critical pressure45.191 bar
Acentric factor (Ambrose–Walton)0.24986 -

Applying the formula below gives:

ResultValue
Vapour pressure, Riedel7.7352 bar
Vapour pressure, Ambrose–Walton7.6671 bar
Reduced temperature0.79070

Open this example in the calculator and change any input.

Formula

\(\ln p_r = A - \frac{B}{T_r} + C\ln T_r + DT_r^6, \quad \psi = -35 + \frac{36}{T_{br}} + 42\ln T_{br} - T_{br}^6, \quad \alpha_c = \frac{3.758K\psi + \ln(p_c/1.01325\ \mathrm{bar})}{K\psi - \ln T_{br}}\)

\(\ln p_r = f^{(0)} + \omega f^{(1)} + \omega^2 f^{(2)}, \quad f^{(0)} = \frac{-5.97616\tau + 1.29874\tau^{1.5} - 0.60394\tau^{2.5} - 1.06841\tau^5}{T_r}, \ \tau = 1 - T_r\)

\(f^{(1)} = \frac{-5.03365\tau + 1.11505\tau^{1.5} - 5.41217\tau^{2.5} - 7.46628\tau^5}{T_r}, \quad f^{(2)} = \frac{-0.64771\tau + 2.41539\tau^{1.5} - 4.26979\tau^{2.5} + 3.25259\tau^5}{T_r}\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(T_b\) Normal boiling point K
\(T_c\) Critical temperature K
\(p_c\) Critical pressure Pa
\(\omega\) Acentric factor (Ambrose–Walton) -
\(p_{Riedel}\) Vapour pressure, Riedel Pa
\(p_{AW}\) Vapour pressure, Ambrose–Walton Pa
\(T_r\) Reduced temperature -

Method and standards

Riedel's equation with K = 0.0838; Ambrose–Walton corresponding states.

Where it is used

  • Vapour pressure where no Antoine constants are available.
  • Checking supplier data.

Common mistakes

  • Using T above T_c.
  • Mixing gauge and absolute critical pressure.

Assumptions and limits

  • Organic compounds; poorer near the triple point.
  • T_b feeds Riedel and ω feeds Ambrose–Walton; they are entered separately, so a difference above 10 % between the two results is flagged as a sign of inconsistent data.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2
  • Eqs. (2-28)
  • (2-28a) (Riedel) and (2-29) (Ambrose–Walton, Lee–Kesler form)
  • with the chlorobenzene example

Questions and answers

Which method should I use?

Riedel when you know the boiling point and critical constants; Ambrose–Walton when you know the acentric factor. Agreement between them is a useful check.

What does Perry's example give?

Chlorobenzene at 500 K: 7.74 bar by Riedel against 7.67 bar in DIPPR.

Can I use it for water or alcohols?

With care: strongly polar and associating liquids are less accurate. Use IAPWS for water.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.