Worked example
Example: Chlorobenzene 500 K (Perry's example: 7.74 bar Riedel). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature | 226.85 °C |
| Normal boiling point | 131.72 °C |
| Critical temperature | 359.20 °C |
| Critical pressure | 45.191 bar |
| Acentric factor (Ambrose–Walton) | 0.24986 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour pressure, Riedel | 7.7352 bar |
| Vapour pressure, Ambrose–Walton | 7.6671 bar |
| Reduced temperature | 0.79070 |
Open this example in the calculator and change any input.
Formula
\(\ln p_r = A - \frac{B}{T_r} + C\ln T_r + DT_r^6, \quad \psi = -35 + \frac{36}{T_{br}} + 42\ln T_{br} - T_{br}^6, \quad \alpha_c = \frac{3.758K\psi + \ln(p_c/1.01325\ \mathrm{bar})}{K\psi - \ln T_{br}}\)
\(\ln p_r = f^{(0)} + \omega f^{(1)} + \omega^2 f^{(2)}, \quad f^{(0)} = \frac{-5.97616\tau + 1.29874\tau^{1.5} - 0.60394\tau^{2.5} - 1.06841\tau^5}{T_r}, \ \tau = 1 - T_r\)
\(f^{(1)} = \frac{-5.03365\tau + 1.11505\tau^{1.5} - 5.41217\tau^{2.5} - 7.46628\tau^5}{T_r}, \quad f^{(2)} = \frac{-0.64771\tau + 2.41539\tau^{1.5} - 4.26979\tau^{2.5} + 3.25259\tau^5}{T_r}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Temperature | K |
| \(T_b\) | Normal boiling point | K |
| \(T_c\) | Critical temperature | K |
| \(p_c\) | Critical pressure | Pa |
| \(\omega\) | Acentric factor (Ambrose–Walton) | - |
| \(p_{Riedel}\) | Vapour pressure, Riedel | Pa |
| \(p_{AW}\) | Vapour pressure, Ambrose–Walton | Pa |
| \(T_r\) | Reduced temperature | - |
Method and standards
Riedel's equation with K = 0.0838; Ambrose–Walton corresponding states.
Where it is used
- Vapour pressure where no Antoine constants are available.
- Checking supplier data.
Common mistakes
- Using T above T_c.
- Mixing gauge and absolute critical pressure.
Assumptions and limits
- Organic compounds; poorer near the triple point.
- T_b feeds Riedel and ω feeds Ambrose–Walton; they are entered separately, so a difference above 10 % between the two results is flagged as a sign of inconsistent data.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2
- Eqs. (2-28)
- (2-28a) (Riedel) and (2-29) (Ambrose–Walton, Lee–Kesler form)
- with the chlorobenzene example
Questions and answers
Which method should I use?
Riedel when you know the boiling point and critical constants; Ambrose–Walton when you know the acentric factor. Agreement between them is a useful check.
What does Perry's example give?
Chlorobenzene at 500 K: 7.74 bar by Riedel against 7.67 bar in DIPPR.
Can I use it for water or alcohols?
With care: strongly polar and associating liquids are less accurate. Use IAPWS for water.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.