Worked example
Example: 1,4-Dioxane 320 K (Perry's example: Cp/R 18.58). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature | 46.850 °C |
| Critical temperature | 323.85 °C |
| Acentric factor | 0.27930 - |
| Ideal-gas heat capacity at T (J/(mol·K)) | 99.275 - |
| Molar mass | 88.106 kg/kmol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Liquid heat capacity (J/(mol·K)) | 154.49 |
| Liquid specific heat | 1.7534 kJ/(kg·K) |
| Residual heat capacity (J/(mol·K)) | 55.211 |
Open this example in the calculator and change any input.
Formula
\(\frac{C_p - C_p^\circ}{R} = 1.586 + \frac{0.49}{1 - T_r} + \omega\left[4.2775 + \frac{6.3(1 - T_r)^{1/3}}{T_r} + \frac{0.4355}{1 - T_r}\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Temperature | K |
| \(T_c\) | Critical temperature | K |
| \(\omega\) | Acentric factor | - |
| \(C_p^\circ\) | Ideal-gas heat capacity at T (J/(mol·K)) | - |
| \(M\) | Molar mass | kg/kmol |
| \(C_p\) | Liquid heat capacity (J/(mol·K)) | - |
| \(c_p\) | Liquid specific heat | J/(kg·K) |
| \(C_p - C_p^\circ\) | Residual heat capacity (J/(mol·K)) | - |
Method and standards
Lee–Kesler corresponding states.
Where it is used
- Liquid heating duties for solvents.
- Heat balances for organic streams.
Common mistakes
- Entering C_p° at another temperature.
- Using for water or alcohols.
Assumptions and limits
- Nonpolar or slightly polar organic liquids.
- The liquid state is not checked: make sure T lies between the melting and boiling points. At low reduced temperatures (below about 0.4) a note appears, because the (1 − T_r)^⅓/T_r term then grows large.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2
- Eq. (2-55) (Lee–Kesler) with the 1
- 4-dioxane example
Questions and answers
What does Perry's example give?
1,4-dioxane at 320 K: C_p/R = 18.58, C_p = 154.5 J/(mol·K), 4.6 % below DIPPR.
Where do I get C_p°?
From ideal-gas heat-capacity polynomials or group contributions at the same temperature.
Why does it fail near T_c?
Liquid C_p really does rise steeply there; the equation's 1/(1 − T_r) terms follow it but lose accuracy.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.