Ideal-Gas Heat Capacity: Mean c_p, Enthalpy and Entropy Change

Heat capacity at two temperatures, mean heat capacity, enthalpy change and entropy change of an ideal gas from user coefficients of c_p = a + bT + cT² + dT³.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Oxygen-like, 25 to 500 °CConstant cp 29.1 (air-like), 300 to 400 K

Results

c_p at T₁ (J/(mol·K))29.100
c_p at T₂ (J/(mol·K))29.100
Mean c_p between T₁ and T₂1.0048kJ/(kg·K)
Enthalpy change100.48kJ/kg
Entropy change at constant pressure0.28907kJ/(kg·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Oxygen-like, 25 to 500 °C. The inputs, in the units selected above:

InputValue
a (J/(mol·K))28.110 -
b (J/(mol·K²))-3.6800e-06 -
c (J/(mol·K³))1.7460e-05 -
d (J/(mol·K⁴))-1.0650e-08 -
Temperature 125.000 °C
Temperature 2500.00 °C
Molar mass32.000 kg/kmol

Applying the formula below gives:

ResultValue
c_p at T₁ (J/(mol·K))29.379
c_p at T₂ (J/(mol·K))33.622
Mean c_p between T₁ and T₂0.98398 kJ/(kg·K)
Enthalpy change467.39 kJ/kg
Entropy change at constant pressure0.92748 kJ/(kg·K)

Open this example in the calculator and change any input.

Formula

\(c_p = a + bT + cT^2 + dT^3, \quad \Delta h = \int c_p\,dT, \quad \Delta s = \int\frac{c_p}{T}dT\)

Variables

Symbol Meaning SI unit
\(a\) a (J/(mol·K)) -
\(b\) b (J/(mol·K²)) -
\(c\) c (J/(mol·K³)) -
\(d\) d (J/(mol·K⁴)) -
\(T_1\) Temperature 1 K
\(T_2\) Temperature 2 K
\(M\) Molar mass kg/kmol
\(c_p(T_1)\) c_p at T₁ -
\(c_p(T_2)\) c_p at T₂ (J/(mol·K)) -
\(\bar c_p\) Mean c_p between T₁ and T₂ J/(kg·K)
\(\Delta h\) Enthalpy change J/kg
\(\Delta s\) Entropy change at constant pressure J/(kg·K)

Method and standards

Polynomial integration (per mole, then per kg).

Where it is used

  • Gas heating duties.
  • Combustion and reactor balances.

Common mistakes

  • Using coefficients outside their range.
  • Mixing molar and mass bases.

Assumptions and limits

  • Ideal gas.
  • Coefficients must give c_p in J/(mol·K) with T in kelvin (kJ/(kmol·K) has the same numbers). Sets in calories or with T in °C must be converted first. c_p at T₁ and T₂ is shown per mole; the mean c_p, Δh and Δs are per kg.
  • The coefficients' fitted temperature range is not checked: keep T₁ and T₂ inside it.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2 (ideal-gas heat capacity correlations)
  • Integration of c_p(T) (definitions)

Questions and answers

Why a mean c_p?

Δh = c̄_p ΔT exactly when c̄_p is the integral average between the two temperatures.

Where do coefficients come from?

Property databases and textbooks; check the temperature range they were fitted for.

What do the defaults represent?

Illustrative coefficients similar to oxygen's, between 25 and 500 °C; they are not taken from a particular table, so enter your own.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.