Gas Viscosity at High Pressure (Jossi–Stiel–Thodos)

Viscosity of a nonpolar gas at high pressure from its low-pressure viscosity and reduced density by the Jossi–Stiel–Thodos residual correlation (Perry Eq. 2-88).

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: CO2 350 K, 20 MPa (Perry's example: 0.0489 mPa s)Methane 300 K, 10 MPa

Results

Nonpolar gases; Perry's quotes about 9 %. Estimate for design; use measured data where they exist.

Reduced density0.45666
Viscosity-reducing parameter (1/(mPa·s))470.68
Viscosity at T and p0.013736cP
Pressure correction factor1.2264

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: CO2 350 K, 20 MPa (Perry's example: 0.0489 mPa s). The inputs, in the units selected above:

InputValue
Temperature76.850 °C
Pressure200.00 bar
Compressibility factor at T and p0.49830 -
Critical temperature31.060 °C
Critical pressure73.830 bar
Critical compressibility factor0.27400 -
Molar mass44.010 kg/kmol
Low-pressure viscosity at T0.017400 cP

Applying the formula below gives:

ResultValue
Reduced density1.2947
Viscosity-reducing parameter (1/(mPa·s))224.08
Viscosity at T and p0.048854 cP
Pressure correction factor2.8077

Open this example in the calculator and change any input.

Formula

\(\left[(\eta - \eta^\circ)\xi + 1\right]^{1/4} = 1.0230 + 0.23364\rho_r + 0.58533\rho_r^2 - 0.40758\rho_r^3 + 0.093324\rho_r^4\)

\(\xi = 2173.4\,T_c^{1/6}M^{-1/2}p_c^{-2/3}\ \ (T_c\ \mathrm{K},\ p_c\ \mathrm{MPa}), \quad \rho_r = \frac{pZ_cT_c}{ZTp_c}\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(p\) Pressure Pa
\(Z\) Compressibility factor at T and p -
\(T_c\) Critical temperature K
\(p_c\) Critical pressure Pa
\(Z_c\) Critical compressibility factor -
\(M\) Molar mass kg/kmol
\(\eta^\circ\) Low-pressure viscosity at T Pa·s
\(\rho_r\) Reduced density -
\(\xi\) Viscosity-reducing parameter (1/(mPa·s)) -
\(\eta\) Viscosity at T and p Pa·s
\(\eta/\eta^\circ\) Pressure correction factor -

Method and standards

Residual viscosity correlation.

Where it is used

  • Supercritical CO₂, high-pressure gas lines and compressors.

Common mistakes

  • Using it for polar gases.
  • Using a Z for another condition.

Assumptions and limits

  • Nonpolar gases; 0.1 < ρ_r < 3.
  • Z and the low-pressure viscosity are inputs and are not checked against T and p: Z must come from an equation of state at the same T and p (Z = 1 at high pressure gives a wrong reduced density), and the low-pressure viscosity must be at the same T.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2
  • Eqs. (2-88) and (2-93) (Jossi, Stiel and Thodos) with the CO₂ example

Questions and answers

What does Perry's example give?

CO₂ at 350 K and 20 MPa: 0.0489 mPa·s against 0.0473 measured (3.4 %).

Where do I get Z?

From an equation of state (Peng–Robinson or Lee–Kesler) at the same T and p.

Why is viscosity a function of density?

At high pressure, molecules are close and collisions transfer momentum more effectively; the excess over the dilute-gas value depends mainly on density.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.