FireCADCalc

HTST Pasteuriser: Regeneration Efficiency and Duties

Regeneration efficiency of a plate pasteuriser and the heating and cooling duties left for hot water and chilled water, from milk flow and the section temperatures.

Food, dairy and textile

Inputs

Examples: HTST 20 000 kg/h, 4 → 68 → 72 °CLower regeneration

Results

Regeneration of 90–95 % is normal for HTST milk; the pasteurised side must stay at higher pressure than the raw side.

Regeneration efficiency94.118%
Heat recovered1,397.3kW
Heating duty87.333kW
Cooling duty87.333kW
Pasteurised milk leaving regeneration8.0000°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: HTST 20 000 kg/h, 4 → 68 → 72 °C. The inputs, in the units selected above:

InputValue
Milk flow20,000 kg/h
Milk specific heat3.9300 kJ/(kg·K)
Raw milk in4.0000 °C
Milk leaving regeneration (heated side)68.000 °C
Pasteurisation temperature72.000 °C
Milk out after cooling4.0000 °C

Applying the formula below gives:

ResultValue
Regeneration efficiency94.118 %
Heat recovered1,397.3 kW
Heating duty87.333 kW
Cooling duty87.333 kW
Pasteurised milk leaving regeneration8.0000 °C

Open this example in the calculator and change any input.

Formula

\(R = \frac{T_2 - T_1}{T_p - T_1}, \quad Q_h = \dot M c_p(T_p - T_2), \quad T_3 = T_p - (T_2 - T_1)\)

Variables

Symbol Meaning SI unit
\(\dot M\) Milk flow kg/s
\(c_p\) Milk specific heat J/(kg·K)
\(T_1\) Raw milk in K
\(T_2\) Milk leaving regeneration (heated side) K
\(T_p\) Pasteurisation temperature K
\(T_o\) Milk out after cooling K
\(R\) Regeneration efficiency -
\(Q_r\) Heat recovered W
\(Q_h\) Heating duty W
\(Q_c\) Cooling duty W
\(T_3\) Pasteurised milk leaving regeneration K

Method and standards

Energy balance with equal flows and specific heats on both sides.

Where it is used

  • Pasteuriser design and audits.

Common mistakes

  • Using different flows on both sides.
  • Ignoring holding tube losses.

Assumptions and limits

  • Equal mass flows and c_p; no losses.
  • The cooled milk T_o must not exceed T₃. Regeneration above 95 % (a small approach T_p − T₂) is flagged: it needs a very large plate area.

References

  • Mass and energy balances (definitions): regeneration efficiency = heat recovered / heat needed from raw-milk to pasteurisation temperature

Questions and answers

What is regeneration efficiency?

The temperature rise in regeneration as a share of the rise to pasteurisation temperature.

Why is high regeneration cheaper to run?

Hot pasteurised milk preheats the cold raw milk, cutting both heating and cooling.

What limits it?

Plate area and the pressure drop; 95 % needs a large regeneration section.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.