FireCADCalc

Tea Withering: Water Removed and Air Flow

Water to remove from green leaf during withering and the air flow and heater duty to do it, from leaf rate, moisture contents and air conditions.

Food, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative 1 t/h of green leafMonsoon, humid air heated moreDry season, unheated air

Accepted: 0.36 to 36,000 kg/h
Accepted: 50 to 95 %
Accepted: 40 to 90 %
Accepted: 0 to 50 °C
Accepted: 0 to 100 %
Accepted: 0 to 60 °C
Accepted: 0 to 60 °C
Accepted: 0.8 to 1.1 bar

Results

Withering removes part of the leaf's water so it rolls and ferments well: from about 78 % to 65–70 % moisture for black tea. The water removed follows from a balance on the leaf solids. Air passing through the troughs cools along a constant-enthalpy line, picking up water; its humidity rise sets the air flow. Warming humid air a few degrees greatly increases its drying capacity, but leaf temperature should stay below about 35 °C. In damp weather part of the air is recirculated and heated to keep its humidity pick-up useful.

Water removed312.50kg/h
Dry air flow110,182kg/h
Air volume flow at the fan (heated air)96,644m³/h
Relative humidity of the air leaving90.973%
Heater duty252.36kW
Withering loss as a share of green leaf31.250%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 t/h of green leaf. The inputs, in the units selected above:

InputValue
Green leaf rate1,000.0 kg/h
Green leaf moisture (wet basis)78.000 %
Withered leaf moisture (wet basis)68.000 %
Ambient air temperature22.000 °C
Ambient relative humidity80.000 %
Air temperature after heating30.000 °C
Air temperature leaving the leaf bed23.000 °C
Pressure1.0132 bar

Applying the formula below gives:

ResultValue
Water removed312.50 kg/h
Dry air flow110,182 kg/h
Air volume flow at the fan (heated air)96,644 m³/h
Relative humidity of the air leaving90.973 %
Heater duty252.36 kW
Withering loss as a share of green leaf31.250 %

Open this example in the calculator and change any input.

Formula

\(\dot m_w = \dot m_g\frac{w_0 - w_1}{1 - w_1}, \quad h(T_{in}, x_a) = h(T_{out}, x_o), \quad \dot m_a = \frac{\dot m_w}{x_o - x_a}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) Green leaf rate kg/s
\(w_0\) Green leaf moisture (wet basis) -
\(w_1\) Withered leaf moisture (wet basis) -
\(T_a\) Ambient air temperature K
\(\varphi_a\) Ambient relative humidity -
\(T_{in}\) Air temperature after heating K
\(T_{out}\) Air temperature leaving the leaf bed K
\(p\) Pressure Pa
\(\dot m_w\) Water removed kg/s
\(\dot m_a\) Dry air flow kg/s
\(\dot V\) Air volume flow at the fan (heated air) m³/s
\(\varphi_{out}\) Relative humidity of the air leaving -
\(\dot Q\) Heater duty W
\(m_w/m_g\) Withering loss as a share of green leaf -

Method and standards

Tea withering.

Where it is used

  • Tea factory trough design and operation.
  • Monsoon-season withering planning.

Common mistakes

  • Using wet-basis loss as the water removed.
  • Overheating the air and scorching the leaf.

Assumptions and limits

  • Adiabatic trough; steady state.

References

  • Psychrometrics: humidity ratio 0.621945 p_v/(p − p_v)
  • humid enthalpy 1006 t + x(2 501 000 + 1860 t)
  • saturation pressure from IAPWS-IF97

Questions and answers

How much water is removed in withering?

From 78 % to 68 % moisture, about 31 % of the green leaf weight.

Why heat the air only a few degrees?

A small rise sharply lowers its relative humidity and raises drying capacity without damaging the leaf.

What do the defaults represent?

An illustrative 1 t/h of green leaf withered from 78 % to 68 % with air at 22 °C and 80 % RH heated to 30 °C, leaving at 23 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.