FireCADCalc

Tea Dryer: Water Evaporated and Fuel per kg of Made Tea

Water evaporated, heat and fuel per kg of made tea in a tea dryer, from made tea output, moisture of fermented leaf and made tea, dryer efficiency and fuel.

Food, dairy and textile

Inputs

Examples: Illustrative 250 kg/h firewood-fired dryerCoal-fired ECP dryerGas-fired fluid-bed dryer

Accepted: 0.36 to 36,000 kg/h
Accepted: 40 to 80 %
Accepted: 0 to 10 %
Accepted: 20 to 90 %
Accepted: 10,000 to 50,000 kJ/kg
Accepted: 30 to 100 %
Accepted: 2,000 to 3,000 kJ/kg

Results

Each kg of made tea at about 3 % moisture comes from fermented leaf (dhool) at 60–65 % moisture, so around 1.5–1.7 kg of water is evaporated per kg of made tea. The heat to the dryer air is the evaporation duty over the dryer's thermal efficiency, and the fuel is that heat over the heater efficiency and the fuel's calorific value. Typical figures are 1.5–2.5 kg of firewood or 0.6–1 kg of coal per kg of made tea; higher figures show heat losses, wet fuel or excessive exhaust temperature.

Water evaporated388.16kg/h
Water per kg of made tea1.5526
Heat to the dryer air560.67kW
Fuel use192.23kg/h
Fuel per kg of made tea0.76892

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 kg/h firewood-fired dryer. The inputs, in the units selected above:

InputValue
Made tea output250.00 kg/h
Moisture of fermented leaf (dhool, wet basis)62.000 %
Moisture of made tea (wet basis)3.0000 %
Dryer thermal efficiency50.000 %
Fuel net calorific value15,000 kJ/kg
Air heater efficiency70.000 %
Heat per kg of water (latent plus sensible)2,600.0 kJ/kg

Applying the formula below gives:

ResultValue
Water evaporated388.16 kg/h
Water per kg of made tea1.5526
Heat to the dryer air560.67 kW
Fuel use192.23 kg/h
Fuel per kg of made tea0.76892

Open this example in the calculator and change any input.

Formula

\(\dot m_w = \dot m_t(1 - w_f)\left(\frac{w_i}{1 - w_i} - \frac{w_f}{1 - w_f}\right), \quad \dot m_{fuel} = \frac{\dot m_w\lambda}{\eta_d\eta_h NCV}\)

Variables

Symbol Meaning SI unit
\(\dot m_t\) Made tea output kg/s
\(w_i\) Moisture of fermented leaf (dhool, wet basis) -
\(w_f\) Moisture of made tea (wet basis) -
\(\eta_d\) Dryer thermal efficiency -
\(NCV\) Fuel net calorific value J/kg
\(\eta_h\) Air heater efficiency -
\(\lambda\) Heat per kg of water (latent plus sensible) J/kg
\(\dot m_w\) Water evaporated kg/s
\(m_w/m_t\) Water per kg of made tea -
\(\dot Q\) Heat to the dryer air W
\(\dot m_{fuel}\) Fuel use kg/s
\(m_{fuel}/m_t\) Fuel per kg of made tea -

Method and standards

Tea dryer.

Where it is used

  • Tea factory energy audits.
  • Comparing firewood, coal, gas and heat pump dryers.

Common mistakes

  • Using wet-basis moisture difference as water removed.
  • Using gross calorific value with wet firewood.

Assumptions and limits

  • Steady drying; efficiencies cover all losses.

References

  • Mass and energy balance of a tea dryer

Questions and answers

How much water is removed per kg of made tea?

About 1.6 kg from dhool at 62 % to made tea at 3 %.

How much fuel does a tea dryer use?

Typically 1.5–2.5 kg of firewood per kg of made tea; the defaults give about 0.8 kg for 15 MJ/kg wood at 50 % and 70 % efficiencies.

What do the defaults represent?

An illustrative factory making 250 kg/h of tea from dhool at 62 % moisture, firewood of 15 MJ/kg, dryer 50 % and heater 70 % efficient.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.