Worked example
Example: Illustrative 250 kg/h firewood-fired dryer. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Made tea output | 250.00 kg/h |
| Moisture of fermented leaf (dhool, wet basis) | 62.000 % |
| Moisture of made tea (wet basis) | 3.0000 % |
| Dryer thermal efficiency | 50.000 % |
| Fuel net calorific value | 15,000 kJ/kg |
| Air heater efficiency | 70.000 % |
| Heat per kg of water (latent plus sensible) | 2,600.0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water evaporated | 388.16 kg/h |
| Water per kg of made tea | 1.5526 |
| Heat to the dryer air | 560.67 kW |
| Fuel use | 192.23 kg/h |
| Fuel per kg of made tea | 0.76892 |
Open this example in the calculator and change any input.
Formula
\(\dot m_w = \dot m_t(1 - w_f)\left(\frac{w_i}{1 - w_i} - \frac{w_f}{1 - w_f}\right), \quad \dot m_{fuel} = \frac{\dot m_w\lambda}{\eta_d\eta_h NCV}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_t\) | Made tea output | kg/s |
| \(w_i\) | Moisture of fermented leaf (dhool, wet basis) | - |
| \(w_f\) | Moisture of made tea (wet basis) | - |
| \(\eta_d\) | Dryer thermal efficiency | - |
| \(NCV\) | Fuel net calorific value | J/kg |
| \(\eta_h\) | Air heater efficiency | - |
| \(\lambda\) | Heat per kg of water (latent plus sensible) | J/kg |
| \(\dot m_w\) | Water evaporated | kg/s |
| \(m_w/m_t\) | Water per kg of made tea | - |
| \(\dot Q\) | Heat to the dryer air | W |
| \(\dot m_{fuel}\) | Fuel use | kg/s |
| \(m_{fuel}/m_t\) | Fuel per kg of made tea | - |
Method and standards
Tea dryer.
Where it is used
- Tea factory energy audits.
- Comparing firewood, coal, gas and heat pump dryers.
Common mistakes
- Using wet-basis moisture difference as water removed.
- Using gross calorific value with wet firewood.
Assumptions and limits
- Steady drying; efficiencies cover all losses.
References
- Mass and energy balance of a tea dryer
Questions and answers
How much water is removed per kg of made tea?
About 1.6 kg from dhool at 62 % to made tea at 3 %.
How much fuel does a tea dryer use?
Typically 1.5–2.5 kg of firewood per kg of made tea; the defaults give about 0.8 kg for 15 MJ/kg wood at 50 % and 70 % efficiencies.
What do the defaults represent?
An illustrative factory making 250 kg/h of tea from dhool at 62 % moisture, firewood of 15 MJ/kg, dryer 50 % and heater 70 % efficient.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)