Worked example
Example: Illustrative 80 um droplet. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial droplet diameter | 80.000 µm |
| Diameter at which a crust forms (0 = complete evaporation) | 50.000 µm |
| Liquid density | 1,100.0 kg/m³ |
| Latent heat of evaporation | 2,400.0 kJ/kg |
| Thermal conductivity of the air film | 0.030000 W/(m·K) |
| Air temperature minus droplet (wet-bulb) temperature | 100.00 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Evaporation time to the critical diameter | 429.00 ms |
| Time for complete evaporation | 704.00 ms |
| Share of the droplet volume evaporated | 75.586 % |
Open this example in the calculator and change any input.
Formula
\(t = \frac{\rho_l \lambda\left(d_0^2 - d_c^2\right)}{8 k \Delta T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_0\) | Initial droplet diameter | m |
| \(d_c\) | Diameter at which a crust forms (0 = complete evaporation) | m |
| \(\rho_l\) | Liquid density | kg/m³ |
| \(\lambda\) | Latent heat of evaporation | J/kg |
| \(k\) | Thermal conductivity of the air film | W/(m·K) |
| \(\Delta T\) | Air temperature minus droplet (wet-bulb) temperature | K |
| \(t\) | Evaporation time to the critical diameter | s |
| \(t_{full}\) | Time for complete evaporation | s |
| \(1 - (d_c/d_0)^3\) | Share of the droplet volume evaporated | - |
Method and standards
Droplet evaporation.
Where it is used
- Spray dryer and spray cooler design.
- Choosing atomiser droplet size.
Common mistakes
- Using the air inlet temperature without the wet-bulb.
- Applying the constant-rate time to the whole drying.
Assumptions and limits
- Spherical droplet; no relative velocity; constant air temperature.
References
- d² law for droplet evaporation with Nu = 2
Questions and answers
How long does an 80 µm droplet take to dry?
About 0.4 s to reach a 50 µm crust in air 100 K above its wet-bulb temperature.
Why is the residence time in a spray dryer much longer?
The falling-rate period inside the crust and the air cooling down the chamber take most of the time.
What do the defaults represent?
An illustrative 80 µm droplet of solution forming a crust at 50 µm, air 100 K above the droplet.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)