Worked example
Example: Rough rice at 30 C, 65 % RH. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air temperature | 30.000 °C |
| Air relative humidity | 65.000 % |
| Constant K | 1.9187e-05 - |
| Constant N | 2.4451 - |
| Constant C (°C) | 51.161 - |
| Grain moisture to find the equilibrium humidity for (dry basis) | 16.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Equilibrium moisture (dry basis) | 14.352 % |
| Equilibrium moisture (wet basis) | 12.551 % |
| Equilibrium relative humidity at the grain moisture | 74.575 % |
Open this example in the calculator and change any input.
Formula
\(1 - \varphi = \exp\left[-K(T + C)M^N\right], \quad M_e = \left[\frac{-\ln(1 - \varphi)}{K(T + C)}\right]^{1/N}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Air temperature | K |
| \(\varphi\) | Air relative humidity | - |
| \(K\) | Constant K | - |
| \(N\) | Constant N | - |
| \(C\) | Constant C (°C) | - |
| \(M\) | Grain moisture to find the equilibrium humidity for (dry basis) | - |
| \(M_e\) | Equilibrium moisture (dry basis) | - |
| \(M_{e,wb}\) | Equilibrium moisture (wet basis) | - |
| \(\varphi_e\) | Equilibrium relative humidity at the grain moisture | - |
Method and standards
Modified Henderson.
Where it is used
- Grain drying and aeration control.
- Safe storage conditions.
Common mistakes
- Using wet-basis moisture in the equation.
- Using constants of another crop.
Assumptions and limits
- Desorption isotherm; T in °C, M in % dry basis.
References
- Modified Henderson equilibrium moisture equation (constants for rough rice as listed in ASABE D245)
Questions and answers
What moisture does rice reach in 30 °C, 65 % RH air?
About 14.4 % on a dry basis (12.6 % wet basis) with the rough rice constants.
Why does warm air dry grain further?
At the same relative humidity, a higher temperature lowers the equilibrium moisture.
What do the defaults represent?
Rough rice constants in air at 30 °C and 65 % relative humidity.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)