Fluid-Bed Dryer Air Flow, Bed Area and Residence Time

Air flow from the heat balance, bed area from the fluidising velocity and solids residence time from the bed depth, for a continuous fluid-bed dryer.

Chemical and fertiliserFood, dairy and textile

Inputs

Examples: Illustrative 500 kg/h fluid-bed dryerGranulate dryer, gentle airMineral dryer, hot air

Accepted: 0.36 to 180,000 kg/h
Accepted: 0.36 to 360,000 kg/h
Accepted: 0.5 to 4 kJ/(kg·K)
Accepted: 0 to 200 K
Accepted: 26.85 to 726.85 °C
Accepted: 16.85 to 426.85 °C
Accepted: 0 to 100 %
Accepted: 0.05 to 5 m/s
Accepted: 100 to 3,000 kg/m³
Accepted: 20 to 3,000 mm

Results

The air gives up sensible heat between inlet and outlet: ṁ_a c_p(T_in − T_out) supplies the heat to evaporate the water (from feed water at 20 °C to vapour at the outlet temperature), to warm the solids and to cover losses. Humid heat is taken as 1006 + 1860 × 0.01 J/(kg·K). The bed area follows from the air density at the inlet temperature and the chosen superficial velocity, which must lie between minimum fluidisation and the elutriation velocity of the fines. The mean residence time is the bed hold-up divided by the solids rate; plug-flow (multi-cell) beds narrow the spread of residence times.

Dry air flow18,704kg/h
Heat supplied to the air425.87kW
Bed (distributor) area7.7853m²
Mean solids residence time42.040min
Humidity pick-up of the air26.733g/kg
Heat per kg of water evaporated3,066.2kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 500 kg/h fluid-bed dryer. The inputs, in the units selected above:

InputValue
Water to evaporate500.00 kg/h
Dry solids rate2,000.0 kg/h
Specific heat of the solids (with residual moisture)1.5000 kJ/(kg·K)
Temperature rise of the solids40.000 K
Air inlet temperature150.00 °C
Air outlet temperature70.000 °C
Heat loss as a share of the useful heat10.000 %
Superficial air velocity in the bed (at inlet temperature)0.80000 m/s
Bed density (fluidised)600.00 kg/m³
Bed depth300.00 mm

Applying the formula below gives:

ResultValue
Dry air flow18,704 kg/h
Heat supplied to the air425.87 kW
Bed (distributor) area7.7853 m²
Mean solids residence time42.040 min
Humidity pick-up of the air26.733 g/kg
Heat per kg of water evaporated3,066.2 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot m_a c_p (T_{in} - T_{out}) = (1 + f_L)\left[\dot m_w(h_v - h_l) + \dot m_s c_s \Delta T_s\right], \quad A = \frac{\dot m_a}{\rho_{in} u}, \quad \tau = \frac{\rho_b A H}{\dot m_s}\)

Variables

Symbol Meaning SI unit
\(\dot m_w\) Water to evaporate kg/s
\(\dot m_s\) Dry solids rate kg/s
\(c_s\) Specific heat of the solids (with residual moisture) J/(kg·K)
\(\Delta T_s\) Temperature rise of the solids K
\(T_{in}\) Air inlet temperature K
\(T_{out}\) Air outlet temperature K
\(f_L\) Heat loss as a share of the useful heat -
\(u\) Superficial air velocity in the bed (at inlet temperature) m/s
\(\rho_b\) Bed density (fluidised) kg/m³
\(H\) Bed depth m
\(\dot m_a\) Dry air flow kg/s
\(\dot Q\) Heat supplied to the air W
\(A\) Bed (distributor) area m²
\(\tau\) Mean solids residence time s
\(\Delta x\) Humidity pick-up of the air kg/kg
\(q_w\) Heat per kg of water evaporated J/kg

Method and standards

Fluid-bed dryer.

Where it is used

  • Granules, grains, chemicals, pharmaceuticals and tea.
  • First sizing before vendor design.

Common mistakes

  • Using the velocity at outlet temperature for the area.
  • Ignoring the heat to warm the solids.

Assumptions and limits

  • Steady state; well-mixed bed; feed water at 20 °C.

References

  • Heat balance and hydrodynamic sizing of a continuous fluid-bed dryer

Questions and answers

How is the bed area chosen?

From the air volume at the inlet temperature divided by the fluidising velocity, usually 2–4 times the minimum fluidisation velocity.

Why is the exhaust temperature important?

Air leaving hotter carries away more heat; a lower outlet temperature raises efficiency but risks wet, sticky product.

What do the defaults represent?

An illustrative dryer evaporating 500 kg/h from 2 t/h of solids, air 150 °C in and 70 °C out, 0.8 m/s, 300 mm bed.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.