Worked example
Example: Illustrative sample weighings. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry solids mass (oven-dry) | 0.50000 kg |
| Sample mass at the first weighing | 0.85000 kg |
| Time of the first weighing | 10.000 min |
| Sample mass at the second weighing | 0.78000 kg |
| Time of the second weighing | 20.000 min |
| Drying surface area | 500.00 cm² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Moisture at the first weighing (dry basis) | 70.000 % |
| Moisture at the second weighing (dry basis) | 56.000 % |
| Drying rate (kg water per kg dry solids per hour) | 0.84000 |
| Drying flux | 8.4000 kg/(m²·h) |
Open this example in the calculator and change any input.
Formula
\(X = \frac{m - m_d}{m_d}, \quad -\frac{dX}{dt} = \frac{X_1 - X_2}{t_2 - t_1}, \quad N = \frac{m_1 - m_2}{A(t_2 - t_1)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_d\) | Dry solids mass (oven-dry) | kg |
| \(m_1\) | Sample mass at the first weighing | kg |
| \(t_1\) | Time of the first weighing | s |
| \(m_2\) | Sample mass at the second weighing | kg |
| \(t_2\) | Time of the second weighing | s |
| \(A\) | Drying surface area | m² |
| \(X_1\) | Moisture at the first weighing (dry basis) | - |
| \(X_2\) | Moisture at the second weighing (dry basis) | - |
| \(-dX/dt\) | Drying rate (kg water per kg dry solids per hour) | - |
| \(N\) | Drying flux | kg/(m²·s) |
Method and standards
Drying rate.
Where it is used
- Laboratory and pilot drying tests.
- Building drying curves for dryer design.
Common mistakes
- Using wet-basis moisture for the rate curve.
- Weighing at irregular conditions.
Assumptions and limits
- Constant air conditions between weighings.
References
- Gravimetric drying-rate measurement
Questions and answers
How do I get the dry mass?
Dry the sample to constant weight in an oven at the end (usually 105 °C) and weigh it.
What does a falling flux mean?
Water is no longer reaching the surface fast enough: the falling-rate period has started.
What do the defaults represent?
An illustrative 0.5 kg (dry) sample of 0.05 m² weighing 0.85 kg at 10 min and 0.78 kg at 20 min.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)