FireCADCalc

Drying Rate from Weighings: Moisture and Flux

Dry-basis moisture at two weighings and the drying rate and flux between them, from the dry solids mass, sample masses, times and drying area.

Inputs

Examples: Illustrative sample weighingsFalling-rate readingsThick cake

Accepted: 1E-6 to 1,000,000 kg
Accepted: 1E-6 to 1,000,000 kg
Accepted: 0 to 166,670 min
Accepted: 1E-6 to 1,000,000 kg
Accepted: 0.016667 to 166,670 min
Accepted: 0.01 to 100,000,000 cm²

Results

Weighing a sample during drying and drying it fully at the end gives its moisture on a dry basis, X = (m − m_d)/m_d. The mass lost between weighings divided by the time and the exposed area is the drying flux; constant flux means constant-rate drying, falling flux the falling-rate period. Plotting the rate against X gives the drying-rate curve used to size dryers.

Moisture at the first weighing (dry basis)30.000%
Moisture at the second weighing (dry basis)22.500%
Drying rate (kg water per kg dry solids per hour)0.075000
Drying flux0.75000kg/(m²·h)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative sample weighings. The inputs, in the units selected above:

InputValue
Dry solids mass (oven-dry)0.50000 kg
Sample mass at the first weighing0.85000 kg
Time of the first weighing10.000 min
Sample mass at the second weighing0.78000 kg
Time of the second weighing20.000 min
Drying surface area500.00 cm²

Applying the formula below gives:

ResultValue
Moisture at the first weighing (dry basis)70.000 %
Moisture at the second weighing (dry basis)56.000 %
Drying rate (kg water per kg dry solids per hour)0.84000
Drying flux8.4000 kg/(m²·h)

Open this example in the calculator and change any input.

Formula

\(X = \frac{m - m_d}{m_d}, \quad -\frac{dX}{dt} = \frac{X_1 - X_2}{t_2 - t_1}, \quad N = \frac{m_1 - m_2}{A(t_2 - t_1)}\)

Variables

Symbol Meaning SI unit
\(m_d\) Dry solids mass (oven-dry) kg
\(m_1\) Sample mass at the first weighing kg
\(t_1\) Time of the first weighing s
\(m_2\) Sample mass at the second weighing kg
\(t_2\) Time of the second weighing s
\(A\) Drying surface area m²
\(X_1\) Moisture at the first weighing (dry basis) -
\(X_2\) Moisture at the second weighing (dry basis) -
\(-dX/dt\) Drying rate (kg water per kg dry solids per hour) -
\(N\) Drying flux kg/(m²·s)

Method and standards

Drying rate.

Where it is used

  • Laboratory and pilot drying tests.
  • Building drying curves for dryer design.

Common mistakes

  • Using wet-basis moisture for the rate curve.
  • Weighing at irregular conditions.

Assumptions and limits

  • Constant air conditions between weighings.

References

  • Gravimetric drying-rate measurement

Questions and answers

How do I get the dry mass?

Dry the sample to constant weight in an oven at the end (usually 105 °C) and weigh it.

What does a falling flux mean?

Water is no longer reaching the surface fast enough: the falling-rate period has started.

What do the defaults represent?

An illustrative 0.5 kg (dry) sample of 0.05 m² weighing 0.85 kg at 10 min and 0.78 kg at 20 min.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.