FireCADCalc

Steam-Heated Drum Dryer Evaporation Capacity

Evaporation and product output of a steam-heated drum dryer from the drum size, wrap angle, overall coefficient, steam and product temperatures and moistures.

Food, dairy and textile

Inputs

Examples: Illustrative 1.2 x 3 m drumMilk powder double drumStarch flaker

Accepted: 0.2 to 6 m
Accepted: 0.2 to 10 m
Accepted: 30 to 95 %
Accepted: 100 to 5,000 W/(m²·K)
Accepted: 100 to 200 °C
Accepted: 26.85 to 146.85 °C
Accepted: 2,000 to 2,600 kJ/kg
Accepted: 1 to 90 %
Accepted: 50 to 100 %

Results

Steam condensing inside the drum heats the thin film of product on the outside; the heat flow is U A (T_s − T_p) over the covered part of the drum. Almost all of it evaporates water, so evaporation ≈ Q/λ. A water balance on the solids gives the product rate: each kg of product removes (1/x_f − 1/x_p) kg of water per kg of solids. Feed preheating, sensible heat and heat losses are neglected here, so the true output is somewhat lower. Typical U values are 1000–2000 W/(m²·K) for thin films.

Effective heated area4.0212m²
Heat transferred331.75kW
Evaporation526.13kg/h
Product output441.64kg/h
Feed rate951.99kg/h
Steam condensed (latent heat at the steam temperature)565.04kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.2 x 3 m drum. The inputs, in the units selected above:

InputValue
Drum diameter1.2000 m
Drum length3.0000 m
Share of the drum surface covered by product75.000 %
Overall heat transfer coefficient1,000.0 W/(m²·K)
Steam temperature inside the drum165.00 °C
Mean product temperature on the drum100.00 °C
Latent heat at the product temperature2,257.0 kJ/kg
Feed solids (wet basis)30.000 %
Product solids (wet basis)96.000 %

Applying the formula below gives:

ResultValue
Effective heated area8.4823 m²
Heat transferred551.35 kW
Evaporation879.42 kg/h
Product output383.75 kg/h
Feed rate1,228.0 kg/h
Steam condensed (latent heat at the steam temperature)960.98 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = U\,\pi D L f\,(T_s - T_p), \quad \dot m_w = \frac{\dot Q}{\lambda}, \quad \dot m_p = \frac{\dot m_w}{1/x_f - 1/x_p}\)

Variables

Symbol Meaning SI unit
\(D\) Drum diameter m
\(L\) Drum length m
\(f\) Share of the drum surface covered by product -
\(U\) Overall heat transfer coefficient W/(m²·K)
\(T_s\) Steam temperature inside the drum K
\(T_p\) Mean product temperature on the drum K
\(\lambda\) Latent heat at the product temperature J/kg
\(x_f\) Feed solids (wet basis) -
\(x_p\) Product solids (wet basis) -
\(A\) Effective heated area m²
\(\dot Q\) Heat transferred W
\(\dot m_w\) Evaporation kg/s
\(\dot m_p\) Product output kg/s
\(\dot m_f\) Feed rate kg/s
\(\dot m_{st}\) Steam condensed (latent heat at the steam temperature) kg/s

Method and standards

Drum dryer.

Where it is used

  • Milk, starch, potato flakes and chemicals.
  • Checking drum dryer throughput.

Common mistakes

  • Using the whole drum area.
  • Ignoring condensate removal (it cuts U sharply).

Assumptions and limits

  • Steady state; sensible heat and losses neglected.

References

  • Conduction drum dryer heat balance

Questions and answers

How much does a drum dryer evaporate?

Typically 15–40 kg/(m²·h) of heated surface, depending on steam pressure and film thickness.

Why use steam at 6–8 bar?

A hotter drum raises the driving temperature difference and output, within what the product can tolerate.

What do the defaults represent?

An illustrative 1.2 m × 3 m drum with 75 % wrap, U = 1000 W/(m²·K), steam at 165 °C, product at 100 °C, 30 % solids feed to 96 %.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.