Worked example
Example: Illustrative 1.2 x 3 m drum. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Drum diameter | 1.2000 m |
| Drum length | 3.0000 m |
| Share of the drum surface covered by product | 75.000 % |
| Overall heat transfer coefficient | 1,000.0 W/(m²·K) |
| Steam temperature inside the drum | 165.00 °C |
| Mean product temperature on the drum | 100.00 °C |
| Latent heat at the product temperature | 2,257.0 kJ/kg |
| Feed solids (wet basis) | 30.000 % |
| Product solids (wet basis) | 96.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Effective heated area | 8.4823 m² |
| Heat transferred | 551.35 kW |
| Evaporation | 879.42 kg/h |
| Product output | 383.75 kg/h |
| Feed rate | 1,228.0 kg/h |
| Steam condensed (latent heat at the steam temperature) | 960.98 kg/h |
Open this example in the calculator and change any input.
Formula
\(\dot Q = U\,\pi D L f\,(T_s - T_p), \quad \dot m_w = \frac{\dot Q}{\lambda}, \quad \dot m_p = \frac{\dot m_w}{1/x_f - 1/x_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Drum diameter | m |
| \(L\) | Drum length | m |
| \(f\) | Share of the drum surface covered by product | - |
| \(U\) | Overall heat transfer coefficient | W/(m²·K) |
| \(T_s\) | Steam temperature inside the drum | K |
| \(T_p\) | Mean product temperature on the drum | K |
| \(\lambda\) | Latent heat at the product temperature | J/kg |
| \(x_f\) | Feed solids (wet basis) | - |
| \(x_p\) | Product solids (wet basis) | - |
| \(A\) | Effective heated area | m² |
| \(\dot Q\) | Heat transferred | W |
| \(\dot m_w\) | Evaporation | kg/s |
| \(\dot m_p\) | Product output | kg/s |
| \(\dot m_f\) | Feed rate | kg/s |
| \(\dot m_{st}\) | Steam condensed (latent heat at the steam temperature) | kg/s |
Method and standards
Drum dryer.
Where it is used
- Milk, starch, potato flakes and chemicals.
- Checking drum dryer throughput.
Common mistakes
- Using the whole drum area.
- Ignoring condensate removal (it cuts U sharply).
Assumptions and limits
- Steady state; sensible heat and losses neglected.
References
- Conduction drum dryer heat balance
Questions and answers
How much does a drum dryer evaporate?
Typically 15–40 kg/(m²·h) of heated surface, depending on steam pressure and film thickness.
Why use steam at 6–8 bar?
A hotter drum raises the driving temperature difference and output, within what the product can tolerate.
What do the defaults represent?
An illustrative 1.2 m × 3 m drum with 75 % wrap, U = 1000 W/(m²·K), steam at 165 °C, product at 100 °C, 30 % solids feed to 96 %.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)