FireCADCalc

Belt (Conveyor) Dryer Area, Length and Belt Speed

Belt area, length and speed of a through-circulation conveyor dryer from the wet feed rate, residence time, bed loading and belt width.

Food, dairy and textile

Inputs

Examples: Illustrative 2 t/h belt dryerThree-pass vegetable dryerThin layer, short time

Accepted: 0.36 to 180,000 kg/h
Accepted: 1 to 1,666.7 min
Accepted: 1 to 500 kg/m²
Accepted: 0.3 to 6 m
Accepted: 1 to 10

Results

A conveyor dryer holds the feed for the residence time, so the wet hold-up is feed rate × time; spread at the chosen bed loading it needs that much belt area. The belt then moves one pass length in the residence time divided by the number of passes. Bed loading (kg of wet feed per m²) is limited by air pressure drop and uneven drying through deep beds; drying trials fix both it and the time. Shrinkage and transfer between belts allow some recovery of area.

Belt area needed80.000m²
Length per pass13.333m
Belt speed0.33333m/min
Wet hold-up on the belt1,600.0kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 t/h belt dryer. The inputs, in the units selected above:

InputValue
Wet feed rate2,000.0 kg/h
Residence time45.000 min
Bed loading of wet feed30.000 kg/m²
Belt width2.5000 m
Number of passes (stacked belts)1.0000 -

Applying the formula below gives:

ResultValue
Belt area needed50.000 m²
Length per pass20.000 m
Belt speed0.44444 m/min
Wet hold-up on the belt1,500.0 kg

Open this example in the calculator and change any input.

Formula

\(A = \frac{\dot m_f\,\tau}{q_b}, \quad L = \frac{A}{nB}, \quad v = \frac{nL}{\tau}\)

Variables

Symbol Meaning SI unit
\(\dot m_f\) Wet feed rate kg/s
\(\tau\) Residence time s
\(q_b\) Bed loading of wet feed kg/m²
\(B\) Belt width m
\(n\) Number of passes (stacked belts) -
\(A\) Belt area needed m²
\(L\) Length per pass m
\(v\) Belt speed m/s
\(m_h\) Wet hold-up on the belt kg

Method and standards

Belt dryer.

Where it is used

  • Vegetables, pasta, tea, rubber and sludge.
  • Layout of conveyor dryers.

Common mistakes

  • Using product rate instead of wet feed rate.
  • Ignoring shrinkage between passes.

Assumptions and limits

  • Uniform loading; constant residence time.

References

  • Hold-up sizing of conveyor dryers

Questions and answers

How is a belt dryer sized?

Hold-up = feed × residence time; area = hold-up / bed loading; length = area / width.

Why use several passes?

Stacking belts saves floor space and turns the product over between passes.

What do the defaults represent?

An illustrative 2 t/h wet feed for 45 min at 30 kg/m² on a 2.5 m belt.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.