Worked example
Example: Illustrative 4.8 x 74 m kiln at 300 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shell outside diameter | 4.8000 m |
| Kiln length | 74.000 m |
| Mean shell temperature | 300.00 °C |
| Ambient temperature | 30.000 °C |
| Shell emissivity | 80.000 % |
| Convective coefficient | 12.000 W/(m²·K) |
| Clinker production | 3,000.0 t/d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Radiation coefficient | 16.712 W/(m²·K) |
| Shell area | 1,115.9 m² |
| Shell heat loss | 8.6506 MW |
| Loss per metre | 116.90 kW/m |
| Loss per kg clinker | 249.14 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\dot Q = (h_r + h_c)\pi DL(T_s - T_0), \quad h_r = \varepsilon\sigma(T_s^2 + T_0^2)(T_s + T_0)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Shell outside diameter | m |
| \(L\) | Kiln length | m |
| \(T_s\) | Mean shell temperature | K |
| \(T_0\) | Ambient temperature | K |
| \(\varepsilon\) | Shell emissivity | - |
| \(h_c\) | Convective coefficient | W/(m²·K) |
| \(\dot m_{cl}\) | Clinker production | kg/s |
| \(h_r\) | Radiation coefficient | W/(m²·K) |
| \(A\) | Shell area | m² |
| \(\dot Q\) | Shell heat loss | W |
| \(\dot Q/L\) | Loss per metre | W/m |
| \(q_{sp}\) | Loss per kg clinker | J/kg |
Method and standards
Shell loss.
Where it is used
- Kiln heat balances.
- Judging refractory condition and insulation upgrades.
Common mistakes
- Using burning-zone temperature for the whole shell.
- Ignoring wind effects on convection.
Assumptions and limits
- Uniform mean shell temperature; grey surface; no shading by tyres.
References
- Radiation and convection from a surface
Questions and answers
How hot do kiln shells run?
About 200–350 °C normally; above 400 °C locally signals coating loss or refractory damage.
Why is the loss so large?
A big hot surface radiates heavily: at 300 °C each square metre loses several kilowatts.
What do the defaults represent?
An illustrative 4.8 m × 74 m kiln with a mean shell temperature of 300 °C, ε 0.8, h_c 12 W/(m²·K), producing 3,000 t/d.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Incropera and DeWitt, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), Peray, The Rotary Cement Kiln, 2nd ed. (Chemical Publishing, 1986)