Worked example
Example: Illustrative 35.5 % raw meal, 6 % hot meal. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Loss on ignition of raw meal | 35.500 % |
| Loss on ignition of hot meal | 6.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Degree of calcination | 88.403 % |
| Share of raw-meal CO₂ still to be released | 11.597 % |
Open this example in the calculator and change any input.
Formula
\(DoC = 1 - \frac{LOI_{hm}(1 - LOI_{rm})}{LOI_{rm}(1 - LOI_{hm})}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(LOI_{rm}\) | Loss on ignition of raw meal | - |
| \(LOI_{hm}\) | Loss on ignition of hot meal | - |
| \(DoC\) | Degree of calcination | - |
| \(\text{CO}_2\ \text{left}\) | Share of raw-meal CO₂ still to be released | - |
Method and standards
Calcination.
Where it is used
- Preheater and calciner performance checks.
- Kiln inlet sampling.
Common mistakes
- Using LOI from samples with recirculated dust or bypass material.
- Ignoring CO₂ from carbonates other than CaCO₃.
Assumptions and limits
- All LOI is carbonate CO₂ (moisture and organics negligible).
References
- Loss-on-ignition calcination balance
Questions and answers
Why not just compare LOI values directly?
The hot meal has lost mass, so its LOI must be referred to the same non-volatile basis as the raw meal.
What calcination is wanted at the kiln inlet?
About 90–95 % with a calciner; higher risks build-ups in the riser.
What do the defaults represent?
An illustrative raw meal with 35.5 % LOI and hot meal at 6 % LOI.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duda, Cement Data Book, Vol. 1, 3rd ed. (Bauverlag, 1985), Alsop, Cement Plant Operations Handbook, 6th ed. (Tradeship, 2014)