Worked example
Example: Illustrative 500 L to 0.1 % salt. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fraction of impurity to leave in (target) | 0.10000 % |
| Impurity rejection | 0 % |
| Product rejection | 99.500 % |
| Retentate volume | 0.50000 m³ |
| Permeate flux | 40.000 L/(m²·h) |
| Membrane area | 20.000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Diavolumes | 6.9078 |
| Buffer volume | 3.4539 m³ |
| Product yield | 96.605 % |
| Processing time | 4.3173 h |
Open this example in the calculator and change any input.
Formula
\(N = \frac{-\ln f}{1 - \sigma_i}, \quad V_b = NV, \quad Y = e^{-N(1 - R_p)}, \quad t = \frac{NV}{JA}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(f\) | Fraction of impurity to leave in (target) | - |
| \(\sigma_i\) | Impurity rejection | - |
| \(R_p\) | Product rejection | - |
| \(V\) | Retentate volume | m³ |
| \(J\) | Permeate flux | m/s |
| \(A\) | Membrane area | m² |
| \(N\) | Diavolumes | - |
| \(V_b\) | Buffer volume | m³ |
| \(Y\) | Product yield | - |
| \(t\) | Processing time | s |
Method and standards
Diafiltration.
Where it is used
- Protein buffer exchange and desalting.
- Dairy and enzyme ultrafiltration.
Common mistakes
- Ignoring partial rejection of the impurity.
- Using flux at a different concentration from operation.
Assumptions and limits
- Constant volume and rejection; well mixed retentate.
References
- Constant-volume diafiltration balance
Questions and answers
How many diavolumes are usual?
Five to ten for buffer exchange of small ions, more if the solute is partly retained or binds to the product.
Why concentrate before diafiltering?
Fewer litres of retentate means less buffer per diavolume; the optimum is usually where the flux-concentration product is greatest.
What do the defaults represent?
An illustrative 500 L retentate washed to 0.1 % of its salt (no rejection) with a 99.5 % retained protein, 40 L/(m²·h) over 20 m².
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Doran, Bioprocess Engineering Principles, 2nd ed. (Academic Press, 2013)