Worked example
Example: Illustrative 100 mmol/L to 90 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial substrate | 100.00 mmol/L |
| Conversion wanted | 90.000 % |
| Michaelis constant | 10.000 mmol/L |
| Maximum rate (per minute in the unit below) | 2.0000 mmol/L |
| Time unit of V_max | 1.0000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Batch time | 56.513 min |
| Substrate left | 10.0000 mmol/L |
| Time if the rate stayed at V_max (zero order) | 45.000 min |
| Time if first order throughout (S ≪ K_m) | 11.513 min |
Open this example in the calculator and change any input.
Formula
\(V_{max}\,t = K_m\ln\frac{S_0}{S} + (S_0 - S)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_0\) | Initial substrate | mol/m³ |
| \(X\) | Conversion wanted | - |
| \(K_m\) | Michaelis constant | mol/m³ |
| \(V_{max}\) | Maximum rate (per minute in the unit below) | mol/m³ |
| \(\text{per}\) | Time unit of V_max | s |
| \(t\) | Batch time | s |
| \(S\) | Substrate left | mol/m³ |
| \(t_0\) | Time if the rate stayed at V_max (zero order) | s |
| \(t_1\) | Time if first order throughout (S ≪ K_m) | s |
Method and standards
Integrated Michaelis–Menten.
Where it is used
- Enzymatic hydrolysis and conversions.
- Sizing batch enzyme reactors.
Common mistakes
- Using the initial rate for the whole batch.
- Mixing time units of V_max.
Assumptions and limits
- No inhibition or enzyme decay; well mixed.
References
- Integrated Michaelis–Menten equation
Questions and answers
Why do the last few per cent take so long?
At low substrate the rate becomes first order and falls in proportion to what is left.
Does this include product inhibition?
No; add it as competitive inhibition if the product binds the enzyme.
What do the defaults represent?
An illustrative 100 mmol/L substrate to 90 % with K_m 10 mmol/L and V_max 2 mmol/(L·min).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Shuler and Kargi, Bioprocess Engineering: Basic Concepts, 2nd ed. (Prentice Hall, 2002)