Worked example
Example: Illustrative 10 m3 fermenter, 500 Nm3/h air. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet air flow (dry, normal) | 500.00 Nm³/h |
| Inlet O₂ (dry) | 20.950 % |
| Inlet CO₂ (dry) | 0.040000 % |
| Exhaust O₂ (dry) | 19.500 % |
| Exhaust CO₂ (dry) | 1.2000 % |
| Broth volume | 10.000 m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Exhaust flow (dry, normal) | 498.17 Nm³/h |
| Oxygen uptake rate | 0.33937 kmol/h |
| CO₂ evolution rate | 0.25779 kmol/h |
| Respiratory quotient | 0.75962 |
| Oxygen uptake per litre of broth per hour | 33.937 mmol/L |
Open this example in the calculator and change any input.
Formula
\(\dot V_{out} = \dot V_{in}\frac{1 - y_{O_2,in} - y_{CO_2,in}}{1 - y_{O_2,out} - y_{CO_2,out}}, \quad RQ = \frac{\dot V_{out}y_{CO_2,out} - \dot V_{in}y_{CO_2,in}}{\dot V_{in}y_{O_2,in} - \dot V_{out}y_{O_2,out}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_{in}\) | Inlet air flow (dry, normal) | Nm³/s |
| \(y_{O_2,in}\) | Inlet O₂ (dry) | - |
| \(y_{CO_2,in}\) | Inlet CO₂ (dry) | - |
| \(y_{O_2,out}\) | Exhaust O₂ (dry) | - |
| \(y_{CO_2,out}\) | Exhaust CO₂ (dry) | - |
| \(V_L\) | Broth volume | m³ |
| \(\dot V_{out}\) | Exhaust flow (dry, normal) | Nm³/s |
| \(OUR\) | Oxygen uptake rate | mol/s |
| \(CER\) | CO₂ evolution rate | mol/s |
| \(RQ\) | Respiratory quotient | - |
| \(OUR/V_L\) | Oxygen uptake per litre of broth per hour | mol/m³ |
Method and standards
Off-gas balance.
Where it is used
- Fermentation monitoring and control.
- Detecting overflow metabolism in fed-batch.
Common mistakes
- Using wet-gas readings.
- Ignoring CO₂ dissolved in the broth at high pH.
Assumptions and limits
- Steady state; inert gas unchanged; dry analysis.
References
- Inert-gas balance off-gas analysis
Questions and answers
Why use a nitrogen balance?
Exhaust flow is rarely measured; nitrogen and argon pass unchanged, so their balance gives it from the gas analysis.
Why must the gases be dry?
Analysers read dry gas; humidity changes between inlet and exhaust would otherwise distort the fractions.
What do the defaults represent?
An illustrative 10 m³ fermenter aerated with 500 Nm³/h of air, exhaust at 19.5 % O₂ and 1.2 % CO₂ dry.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Doran, Bioprocess Engineering Principles, 2nd ed. (Academic Press, 2013)