FireCADCalc

Oxygen Transfer Coefficient kLa by the Van 't Riet Correlation

Volumetric oxygen transfer coefficient of a stirred aerated vessel from power per volume and gas velocity (Van 't Riet), and the oxygen transfer rate.

Distillery and ethanolChemical and fertiliserFood, dairy and textile

Inputs

Examples: Illustrative coalescing, 1.5 kW/m3Non-coalescing medium, 2 kW/m3Gentle aeration 300 W/m3

Accepted: 0.01 to 20 kW/m³
Accepted: 0.1 to 100 mm/s
Accepted: 1 to 50 mg/L
Accepted: 0 to 50 mg/L

Results

Van 't Riet (SI units: P/V in W/m³, v_s in m/s, k_La in 1/s): coalescing k_La = 0.026(P/V)^0.4v_s^0.5; non-coalescing 0.002(P/V)^0.7v_s^0.2. Fits within about ±20–40 % for vessels up to several m³ with water-like viscosity; viscous or mycelial broths transfer much less. OTR = k_La(C* − C_L).

Volumetric mass transfer coefficient174.471/h
Oxygen transfer rate0.87233g/(L·h)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative coalescing, 1.5 kW/m3. The inputs, in the units selected above:

InputValue
Gassed power per volume1.5000 kW/m³
Superficial gas velocity10.000 mm/s
MediumCoalescing (pure water-like)
Saturation dissolved oxygen7.0000 mg/L
Dissolved oxygen in the liquid2.0000 mg/L

Applying the formula below gives:

ResultValue
Volumetric mass transfer coefficient174.47 1/h
Oxygen transfer rate0.87233 g/(L·h)

Open this example in the calculator and change any input.

Formula

\(k_La = 0.026\left(\frac PV\right)^{0.4}v_s^{0.5}\ \text{(coalescing)}, \quad k_La = 0.002\left(\frac PV\right)^{0.7}v_s^{0.2}\ \text{(non-coalescing)}\)

Variables

Symbol Meaning SI unit
\(P/V\) Gassed power per volume W/m³
\(v_s\) Superficial gas velocity m/s
\(\text{medium}\) Medium -
\(C^*\) Saturation dissolved oxygen kg/m³
\(C_L\) Dissolved oxygen in the liquid kg/m³
\(k_La\) Volumetric mass transfer coefficient 1/s
\(OTR\) Oxygen transfer rate kg/(m³·s)

Method and standards

kLa estimate.

Where it is used

  • Fermenter and aerobic reactor design.
  • Scale-up of aeration.

Common mistakes

  • Using ungassed power.
  • Applying it to viscous broths.

Assumptions and limits

  • Water-like viscosity; SI units in the correlation.

References

  • Van 't Riet kLa correlations

Questions and answers

Why do salt solutions transfer oxygen better?

Electrolytes stop bubbles coalescing, keeping them small with more interfacial area.

How do I raise kLa?

More power per volume or more gas; power is usually the more effective lever up to the motor and heat-removal limits.

What do the defaults represent?

An illustrative fermenter at 1.5 kW/m³ gassed power and 10 mm/s superficial gas velocity in a coalescing medium, saturation 7 mg/L and DO 2 mg/L.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

van 't Riet, Review of measuring methods and results in nonviscous gas-liquid mass transfer in stirred vessels, Ind. Eng. Chem. Process Des. Dev. 18, 357 (1979), Doran, Bioprocess Engineering Principles, 2nd ed. (Academic Press, 2013)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.