Worked example
Example: Illustrative chemostat data. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First growth (dilution) rate | 0.050000 1/h |
| Observed yield at the first rate (g biomass/g substrate) | 0.40000 - |
| Second growth (dilution) rate | 0.30000 1/h |
| Observed yield at the second rate | 0.48000 - |
| Growth rate for the prediction | 0.15000 1/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| True growth yield | 0.50000 |
| Maintenance coefficient (g substrate per g biomass per hour) | 0.025000 |
| Observed yield at the growth rate for the prediction | 0.46154 |
| Share of substrate used for maintenance at that rate | 7.6923 % |
Open this example in the calculator and change any input.
Formula
\(\frac1Y = \frac1{Y_G} + \frac{m_s}{\mu}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\mu_1\) | First growth (dilution) rate | 1/s |
| \(Y_1\) | Observed yield at the first rate (g biomass/g substrate) | - |
| \(\mu_2\) | Second growth (dilution) rate | 1/s |
| \(Y_2\) | Observed yield at the second rate | - |
| \(\mu\) | Growth rate for the prediction | 1/s |
| \(Y_G\) | True growth yield | - |
| \(m_s\) | Maintenance coefficient (g substrate per g biomass per hour) | - |
| \(Y\) | Observed yield at the growth rate for the prediction | - |
| \(f_m\) | Share of substrate used for maintenance at that rate | - |
Method and standards
Maintenance model.
Where it is used
- Fed-batch feed design.
- Interpreting chemostat data.
Common mistakes
- Mixing per-second and per-hour rates.
- Fitting through only one point.
Assumptions and limits
- Steady state; maintenance independent of growth rate.
Questions and answers
How do I find the maintenance coefficient?
Plot 1/Y against 1/μ from two or more chemostat runs: the slope is m_s, the intercept 1/Y_G.
Why are yields lower at slow growth?
Maintenance takes a fixed substrate rate per cell, a larger share when growth is slow.
What do the defaults represent?
Illustrative yields of 0.40 g/g at 0.05 /h and 0.48 g/g at 0.3 /h.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Pirt (1965) maintenance model, Shuler and Kargi, Bioprocess Engineering: Basic Concepts, 2nd ed. (Prentice Hall, 2002)