Boiler House Auxiliary Energy per Tonne of Steam (Period Totals)

Auxiliary power consumption of a boiler house in kWh per tonne of steam from feed pump, fan and other energy, with the shares and the power cost per tonne.

Thermal power plantSugar mill and cogenerationPulp and paperBoilerPumpFan and blower

Inputs

Examples: Day: feed pumps 2400 kWh, fans 3000 kWh, other 1100 kWh, 200 t steamOil boiler day: 900, 600, 300 kWh, 120 tPower plant day: 60 000, 45 000, 25 000 kWh, 5000 t

Results

Auxiliary power per tonne of steam15.000kWh/t
Power cost per tonne of steam (your currency)135.00
Total auxiliary energy1,800.0kWh
Share of feed pumps50.000%
Share of fans33.333%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Day: feed pumps 2400 kWh, fans 3000 kWh, other 1100 kWh, 200 t steam. The inputs, in the units selected above:

InputValue
Feed pump energy in the period2,400.0 kWh
Fan energy (FD, ID, PA, SA) in the period3,000.0 kWh
Other auxiliaries (fuel and ash handling, water treatment, lighting)1,100.0 kWh
Steam generated in the period200.00 t
Electricity price per kWh (your currency)8.0000 -

Applying the formula below gives:

ResultValue
Auxiliary power per tonne of steam32.500 kWh/t
Power cost per tonne of steam (your currency)260.00
Total auxiliary energy6,500.0 kWh
Share of feed pumps36.923 %
Share of fans46.154 %

Open this example in the calculator and change any input.

Formula

\(E = E_{fw} + E_{fan} + E_o \qquad SPC = \frac{E}{m_s} \qquad C_t = SPC \cdot c_e \qquad s_{fw} = \frac{E_{fw}}{E} \qquad s_{fan} = \frac{E_{fan}}{E}\)

Variables

Symbol Meaning SI unit
\(E_{fw}\) feed pump energy J
\(E_{fan}\) fan energy J
\(E_o\) other auxiliary energy J
\(m_s\) steam generated kg
\(c_e\) electricity price per kWh –
\(SPC\) auxiliary energy per unit of steam J/kg
\(C_t\) power cost per tonne of steam –
\(E\) total auxiliary energy J
\(s_{fw}\) feed pump share –
\(s_{fan}\) fan share –

Method and standards

Energy audit definition of specific auxiliary consumption; shown in kWh per tonne (1 kWh/t = 3.6 kJ/kg).

Where it is used

  • Daily and monthly boiler house reports.
  • Finding the auxiliaries worth fitting with variable speed drives.
  • Steam cost calculations.

Common mistakes

  • Leaving out fuel handling, ash handling and water treatment.
  • Comparing days with very different loads: kWh per tonne rises at low load.
  • Reading energy meters over a different period than the steam meter.

Assumptions and limits

  • Energy and steam totals for the same period.

References

  • Energy audit definitions (auxiliary energy per unit output)

Questions and answers

How much power does a boiler house use per tonne of steam?

Feed pumps 2400 kWh, fans 3000 kWh and other auxiliaries 1100 kWh for 200 t of steam is 32.5 kWh per tonne; at 8 per kWh that adds 260 to the cost of each tonne. Fans take 46 % and feed pumps 37 %.

What is a good figure?

It depends on fuel, pressure and draught system: oil and gas shell boilers use little, coal and biomass boilers with ID fans, mills and ash handling use much more. Track your own trend and compare similar plants.

Where are the savings?

Usually in fans and pumps on damper or valve control: variable speed drives, correct excess air and fewer leaks cut both.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.