Worked example
Example: Ganapathy Q8.44d case 1: demand 45,000 → 50,000 lb/h (book −572 psi/h). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Drum pressure (absolute) | 42.403 bar |
| Heat to the evaporator | 13,452 kW |
| Feedwater flow | 20,412 kg/h |
| Feedwater temperature | 105.15 °C |
| Steam withdrawn | 22,680 kg/h |
| Mass of metal in the evaporator and drums | 34.019 t |
| Metal specific heat | 0.50240 kJ/(kg·K) |
| Water inventory | 8.1647 t |
| Steam space volume | 3.2564 m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam generated | 22,611 kg/h |
| Rate of pressure change | -1,161.5 Pa/s |
| Rate of pressure change (per minute) | -0.69693 bar/min |
| Stored-energy factor (kJ per bar, fixed unit) | 80,968 |
Open this example in the calculator and change any input.
Formula
\(Q = W_sh_{fg} + (h_l - h_{fw})W_f + \left(W_mc_m\frac{dT_s}{dp} + W_w\frac{dh_l}{dp}\right)\frac{dp}{dt}, \quad \frac{dp}{dt} = \frac{p}{m_s}(W_s - W_l), \ m_s = \frac{V_s}{v_g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Drum pressure (absolute) | Pa |
| \(Q\) | Heat to the evaporator | W |
| \(W_f\) | Feedwater flow | kg/s |
| \(T_{fw}\) | Feedwater temperature | K |
| \(W_l\) | Steam withdrawn | kg/s |
| \(W_m\) | Mass of metal in the evaporator and drums | kg |
| \(c_m\) | Metal specific heat | J/(kg·K) |
| \(W_w\) | Water inventory | kg |
| \(V_s\) | Steam space volume | m³ |
| \(W_s\) | Steam generated | kg/s |
| \(dp/dt\) | Rate of pressure change, shown in Pa/s and in bar/min | Pa/s |
| \(S\) | Stored-energy factor, \(W_m c_m\,dT_s/dp + W_w\,dh_l/dp\), shown in kJ per bar | J/Pa |
Method and standards
Ganapathy's lumped energy balance with IF97 derivatives. The slopes \(dT_s/dp\) and \(dh_l/dp\) are central differences over ±1 % of the drum pressure. Ganapathy's rounded steam-table slopes give somewhat smaller rates than IF97 (see the FAQ).
Where it is used
- Waste heat boiler and HRSG load-following checks.
- Sizing drums for sudden demand.
Common mistakes
- Using the total boiler steel instead of the heated parts.
- Ignoring feedwater control action over longer times.
Assumptions and limits
- Instantaneous; uniform saturation.
- The feedwater must be liquid at the drum pressure (below the saturation temperature).
References
- Ganapathy
- Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
- Q8.44c–d (boiler response to load changes: stored energy of metal, water and steam space); IAPWS-IF97 properties
Questions and answers
Why does pressure fall when demand rises?
More steam leaves than the heat input makes; the deficit comes from the stored energy of water and metal, which releases steam only as pressure (and saturation temperature) falls.
Why does cutting feedwater raise pressure?
Cold feedwater was absorbing heat; without it, more of the heat goes into steam.
What does Ganapathy's example give?
45,000 → 50,000 lb/h demand on a 600 psig waste heat boiler: Ganapathy's rounded steam-table slopes give a fall of 572 psi/h, or a rise of 1,620 psi/h with feedwater cut; IAPWS-IF97 slopes give about 610 and 1,730 psi/h.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.