Drum Pressure Rate After a Load or Feedwater Change

Rate of drum pressure change and steam generation when steam demand, feedwater or heat input changes, from the stored energy of metal and water.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Ganapathy Q8.44d case 1: demand 45,000 → 50,000 lb/h (book −572 psi/h)Case 2: feedwater cut (book +1,620 psi/h)

Results

Instantaneous rates at the moment of the change; controls normally restore the balance. Steam space treated as a perfect gas (Ganapathy's Eq. 86b).

Steam generated22,875kg/h
Rate of pressure change3,310.6Pa/s
Rate of pressure change (per minute)1.9864bar/min
Stored-energy factor (kJ per bar, fixed unit)80,968

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy Q8.44d case 1: demand 45,000 → 50,000 lb/h (book −572 psi/h). The inputs, in the units selected above:

InputValue
Drum pressure (absolute)42.403 bar
Heat to the evaporator13,452 kW
Feedwater flow20,412 kg/h
Feedwater temperature105.15 °C
Steam withdrawn22,680 kg/h
Mass of metal in the evaporator and drums34.019 t
Metal specific heat0.50240 kJ/(kg·K)
Water inventory8.1647 t
Steam space volume3.2564 m³

Applying the formula below gives:

ResultValue
Steam generated22,611 kg/h
Rate of pressure change-1,161.5 Pa/s
Rate of pressure change (per minute)-0.69693 bar/min
Stored-energy factor (kJ per bar, fixed unit)80,968

Open this example in the calculator and change any input.

Formula

\(Q = W_sh_{fg} + (h_l - h_{fw})W_f + \left(W_mc_m\frac{dT_s}{dp} + W_w\frac{dh_l}{dp}\right)\frac{dp}{dt}, \quad \frac{dp}{dt} = \frac{p}{m_s}(W_s - W_l), \ m_s = \frac{V_s}{v_g}\)

Variables

Symbol Meaning SI unit
\(p\) Drum pressure (absolute) Pa
\(Q\) Heat to the evaporator W
\(W_f\) Feedwater flow kg/s
\(T_{fw}\) Feedwater temperature K
\(W_l\) Steam withdrawn kg/s
\(W_m\) Mass of metal in the evaporator and drums kg
\(c_m\) Metal specific heat J/(kg·K)
\(W_w\) Water inventory kg
\(V_s\) Steam space volume m³
\(W_s\) Steam generated kg/s
\(dp/dt\) Rate of pressure change, shown in Pa/s and in bar/min Pa/s
\(S\) Stored-energy factor, \(W_m c_m\,dT_s/dp + W_w\,dh_l/dp\), shown in kJ per bar J/Pa

Method and standards

Ganapathy's lumped energy balance with IF97 derivatives. The slopes \(dT_s/dp\) and \(dh_l/dp\) are central differences over ±1 % of the drum pressure. Ganapathy's rounded steam-table slopes give somewhat smaller rates than IF97 (see the FAQ).

Where it is used

  • Waste heat boiler and HRSG load-following checks.
  • Sizing drums for sudden demand.

Common mistakes

  • Using the total boiler steel instead of the heated parts.
  • Ignoring feedwater control action over longer times.

Assumptions and limits

  • Instantaneous; uniform saturation.
  • The feedwater must be liquid at the drum pressure (below the saturation temperature).

References

  • Ganapathy
  • Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
  • Q8.44c–d (boiler response to load changes: stored energy of metal, water and steam space); IAPWS-IF97 properties

Questions and answers

Why does pressure fall when demand rises?

More steam leaves than the heat input makes; the deficit comes from the stored energy of water and metal, which releases steam only as pressure (and saturation temperature) falls.

Why does cutting feedwater raise pressure?

Cold feedwater was absorbing heat; without it, more of the heat goes into steam.

What does Ganapathy's example give?

45,000 → 50,000 lb/h demand on a 600 psig waste heat boiler: Ganapathy's rounded steam-table slopes give a fall of 572 psi/h, or a rise of 1,620 psi/h with feedwater cut; IAPWS-IF97 slopes give about 610 and 1,730 psi/h.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.