Worked example
Example: Illustrative 6 m3/s, 800 m, 150 m head. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Design flow | 21,600 m³/h |
| Penstock length | 800.00 m |
| Gross head | 150.00 m |
| Pressure rise allowance (water hammer) | 1.3000 - |
| Allowable steel stress × joint efficiency | 120.00 MPa |
| Corrosion allowance and minimum extra | 2.0000 mm |
| Installed steel cost | 3.0000 - |
| Annual capital charge rate | 10.000 % |
| Value of energy (per kWh) | 0.060000 - |
| Equivalent full-flow hours per year | 5,000.0 - |
| Darcy friction factor | 0.013000 - |
| Plant efficiency | 88.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Economic diameter | 1,719.7 mm |
| Shell thickness at the bottom | 15.702 mm |
| Velocity | 2.5833 m/s |
| Friction loss as share of head | 1.3718 % |
| Minimum annual cost (currency) | 122,053 |
Open this example in the calculator and change any input.
Formula
\(C_a(D) = a\,c_s\rho_s\pi D\bar tL + \rho gQh_f(D)\eta\,t_yp_e, \quad t = \frac{p_dD}{2\sigma_a} + c_a, \quad h_f = f\frac{L}{D}\frac{v^2}{2g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Design flow | m³/s |
| \(L\) | Penstock length | m |
| \(H\) | Gross head | m |
| \(k_s\) | Pressure rise allowance (water hammer) | - |
| \(\sigma_a\) | Allowable steel stress × joint efficiency | Pa |
| \(c_a\) | Corrosion allowance and minimum extra | m |
| \(c_s\) | Installed steel cost | - |
| \(a\) | Annual capital charge rate | - |
| \(p_e\) | Value of energy (per kWh) | - |
| \(t_y\) | Equivalent full-flow hours per year | - |
| \(f\) | Darcy friction factor | - |
| \(\eta\) | Plant efficiency | - |
| \(D_{opt}\) | Economic diameter | m |
| \(t\) | Shell thickness at the bottom | m |
| \(v\) | Velocity | m/s |
| \(h_f/H\) | Friction loss as share of head | - |
| \(C_a\) | Minimum annual cost (currency) | - |
Method and standards
Economic diameter.
Where it is used
- Hydro scheme feasibility and penstock design.
- Pumping mains with the same trade-off.
Common mistakes
- Ignoring water hammer pressure in the thickness.
- Using peak rather than average annual flow hours.
Assumptions and limits
- Constant friction factor; steel cost proportional to mass; one diameter along the length.
References
- Economic diameter by annual cost minimisation
Questions and answers
Why is there an economic diameter?
A bigger pipe costs more steel but loses less head; the best size balances the two over the plant's life.
What velocity usually results?
About 3–6 m/s for steel penstocks; small low-head schemes often go slower.
What do the defaults represent?
Illustrative 6 m³/s, 800 m long, 150 m head with 30 % surge allowance, 120 MPa effective stress, steel at 3 per kg, 10 % annual charge, energy at 0.06 per kWh for 5,000 h.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Warnick, Hydropower Engineering (Prentice Hall, 1984), Nag, Power Plant Engineering, 4th ed. (McGraw-Hill, 2014)