FireCADCalc

Economic Penstock Diameter (Steel Cost against Head Loss)

Penstock diameter minimising the annual cost of steel plus energy lost to friction, with the shell thickness from hoop stress and the velocity and head loss.

Thermal power plant

Inputs

Examples: Illustrative 6 m3/s, 800 m, 150 m headSmall scheme 0.5 m3/s, 300 m, 60 mHigh head 3 m3/s, 2 km, 600 m

Accepted: 36 to 1,800,000 m³/h
Accepted: 5 to 20,000 m
Accepted: 2 to 2,000 m
Accepted: 1 to 2
Accepted: 50 to 500 MPa
Accepted: 0 to 10 mm
Accepted: 0.5 to 20
Accepted: 2 to 30 %
Accepted: 0.005 to 1
Accepted: 100 to 8,760
Accepted: 0.008 to 0.04
Accepted: 50 to 100 %

Results

Annual cost = a·c_s·(steel mass) + (lost power)·t_y·p_e, steel mass from hoop thickness t = p_dD/(2σ_a) + c_a (pressure part averaged over the length, rising linearly with depth), lost power ρgQh_fη/1000 kW. The golden-section search finds the minimum. Costs are per kg of steel and per kWh in any one currency; the optimum is flat, so round up to a standard size and check water hammer and buckling.

Economic diameter1,100.5mm
Shell thickness at the bottom29.980mm
Velocity3.1541m/s
Friction loss as share of head1.8437%
Minimum annual cost (currency)329,532

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 6 m3/s, 800 m, 150 m head. The inputs, in the units selected above:

InputValue
Design flow21,600 m³/h
Penstock length800.00 m
Gross head150.00 m
Pressure rise allowance (water hammer)1.3000 -
Allowable steel stress × joint efficiency120.00 MPa
Corrosion allowance and minimum extra2.0000 mm
Installed steel cost3.0000 -
Annual capital charge rate10.000 %
Value of energy (per kWh)0.060000 -
Equivalent full-flow hours per year5,000.0 -
Darcy friction factor0.013000 -
Plant efficiency88.000 %

Applying the formula below gives:

ResultValue
Economic diameter1,719.7 mm
Shell thickness at the bottom15.702 mm
Velocity2.5833 m/s
Friction loss as share of head1.3718 %
Minimum annual cost (currency)122,053

Open this example in the calculator and change any input.

Formula

\(C_a(D) = a\,c_s\rho_s\pi D\bar tL + \rho gQh_f(D)\eta\,t_yp_e, \quad t = \frac{p_dD}{2\sigma_a} + c_a, \quad h_f = f\frac{L}{D}\frac{v^2}{2g}\)

Variables

Symbol Meaning SI unit
\(Q\) Design flow m³/s
\(L\) Penstock length m
\(H\) Gross head m
\(k_s\) Pressure rise allowance (water hammer) -
\(\sigma_a\) Allowable steel stress × joint efficiency Pa
\(c_a\) Corrosion allowance and minimum extra m
\(c_s\) Installed steel cost -
\(a\) Annual capital charge rate -
\(p_e\) Value of energy (per kWh) -
\(t_y\) Equivalent full-flow hours per year -
\(f\) Darcy friction factor -
\(\eta\) Plant efficiency -
\(D_{opt}\) Economic diameter m
\(t\) Shell thickness at the bottom m
\(v\) Velocity m/s
\(h_f/H\) Friction loss as share of head -
\(C_a\) Minimum annual cost (currency) -

Method and standards

Economic diameter.

Where it is used

  • Hydro scheme feasibility and penstock design.
  • Pumping mains with the same trade-off.

Common mistakes

  • Ignoring water hammer pressure in the thickness.
  • Using peak rather than average annual flow hours.

Assumptions and limits

  • Constant friction factor; steel cost proportional to mass; one diameter along the length.

References

  • Economic diameter by annual cost minimisation

Questions and answers

Why is there an economic diameter?

A bigger pipe costs more steel but loses less head; the best size balances the two over the plant's life.

What velocity usually results?

About 3–6 m/s for steel penstocks; small low-head schemes often go slower.

What do the defaults represent?

Illustrative 6 m³/s, 800 m long, 150 m head with 30 % surge allowance, 120 MPa effective stress, steel at 3 per kg, 10 % annual charge, energy at 0.06 per kWh for 5,000 h.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Warnick, Hydropower Engineering (Prentice Hall, 1984), Nag, Power Plant Engineering, 4th ed. (McGraw-Hill, 2014)

Related calculators