Worked example
Example: Illustrative 2 m3/s, 80 m, 300 m of 0.9 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Design flow | 7,200.0 m³/h |
| Gross head | 80.000 m |
| Penstock length | 300.00 m |
| Penstock inside diameter | 0.90000 m |
| Wall roughness (welded steel about 0.05 mm) | 0.050000 mm |
| Sum of minor loss coefficients (intake, bends, valves) | 2.5000 - |
| Water temperature | 15.000 °C |
| Turbine and generator efficiency | 85.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Penstock velocity | 3.1438 m/s |
| Reynolds number | 2,485,016 |
| Darcy friction factor | 0.011744 |
| Head loss | 3.2325 m |
| Net head | 76.767 m |
| Head loss as a share of gross head | 4.0407 % |
| Electrical output | 1,278.7 kW |
Open this example in the calculator and change any input.
Formula
\(h_L = \left(f\frac{L}{D} + \Sigma K\right)\frac{v^2}{2g}, \quad H_n = H_g - h_L, \quad P = \eta\rho gQH_n\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Design flow | m³/s |
| \(H_g\) | Gross head | m |
| \(L\) | Penstock length | m |
| \(D\) | Penstock inside diameter | m |
| \(\varepsilon\) | Wall roughness (welded steel about 0.05 mm) | m |
| \(\Sigma K\) | Sum of minor loss coefficients (intake, bends, valves) | - |
| \(T\) | Water temperature | K |
| \(\eta\) | Turbine and generator efficiency | - |
| \(v\) | Penstock velocity | m/s |
| \(Re\) | Reynolds number | - |
| \(f\) | Darcy friction factor | - |
| \(h_L\) | Head loss | m |
| \(H_n\) | Net head | m |
| \(h_L/H_g\) | Head loss as a share of gross head | - |
| \(P\) | Electrical output | W |
Method and standards
Penstock hydraulics.
Where it is used
- Small and micro hydro design.
- Upgrading old penstocks.
Common mistakes
- Using gross head for turbine selection.
- Ignoring minor losses at the intake.
Assumptions and limits
- Steady full-pipe flow; uniform diameter.
References
- Darcy–Weisbach with Colebrook–White in a hydro penstock
Questions and answers
How big should a penstock be?
Large enough to keep losses near 5–10 % of the gross head; doubling the diameter cuts friction loss about 32 times, but costs more steel.
Why include minor losses?
Trash rack, intake, bends and valves can add as much loss as a short penstock itself.
What do the defaults represent?
An illustrative 2 m³/s small hydro scheme with 80 m gross head and a 300 m, 0.9 m steel penstock, ΣK 2.5, water at 15 °C and 85 % efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)