Worked example
Example: 3 km, 4 m tunnel, 40 m3/s, 6 m friction, 150 m head, 15 m tank. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Headrace tunnel length to the surge tank | 3,000.0 m |
| Tunnel diameter | 4.0000 m |
| Surge tank diameter | 15.000 m |
| Steady flow | 144,000 m³/h |
| Tunnel head loss at the steady flow | 6.0000 m |
| Net head at the turbines | 150.00 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tunnel velocity | 3.1831 m/s |
| Tunnel area | 12.566 m² |
| Surge tank area | 176.71 m² |
| Thoma minimum stable area | 21.639 m² |
| Area ratio (1.5 or more recommended) | 8.1665 |
| Maximum upsurge, frictionless | 14.846 m |
| Mass oscillation period | 412.11 s |
Open this example in the calculator and change any input.
Formula
\(A_{th} = \frac{LA_tV_0^2}{2gh_{f0}H_0}\)
\(Z_{max} = V_0\sqrt{\frac{LA_t}{gA_s}}, \quad T = 2\pi\sqrt{\frac{LA_s}{gA_t}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Headrace tunnel length to the surge tank | m |
| \(D_t\) | Tunnel diameter | m |
| \(D_s\) | Surge tank diameter | m |
| \(Q_0\) | Steady flow | m³/s |
| \(h_{f0}\) | Tunnel head loss at the steady flow | m |
| \(H_0\) | Net head at the turbines | m |
| \(V_0\) | Tunnel velocity | m/s |
| \(A_t\) | Tunnel area | m² |
| \(A_s\) | Surge tank area | m² |
| \(A_{th}\) | Thoma minimum stable area | m² |
| \(A_s/A_{th}\) | Area ratio (1.5 or more recommended) | - |
| \(Z_{max}\) | Maximum upsurge, frictionless | m |
| \(T\) | Mass oscillation period | s |
Method and standards
Rigid-column mass oscillation of a tunnel and simple surge tank.
Where it is used
- Preliminary surge tank sizing.
- Checking stability after changes in head or flow.
Common mistakes
- Using the penstock instead of the headrace length.
- Ignoring the minimum downsurge on load acceptance.
Assumptions and limits
- Simple (unrestricted) tank; small-oscillation Thoma criterion.
Questions and answers
Why must the tank be large enough?
With governed turbines a falling level demands more flow, which lowers the level further; below the Thoma area the mass oscillations grow instead of decaying.
Why use the frictionless upsurge?
It is a safe upper bound for the tank height after full load rejection; detailed design integrates the oscillation with friction.
What do the defaults represent?
A 3 km, 4 m headrace with 40 m³/s, 6 m of friction and 150 m net head, and a 15 m surge tank: about 22 m² Thoma area against 177 m² provided, a frictionless upsurge near 15 m and a period of about 7 minutes.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10, sec. 10.23 (surge tanks); Thoma (1910) stability criterion