Worked example
Example: 2.0 m runner, 12 m3/s, 60 m, 250 rpm, guide vanes 18 deg. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Net head | 60.000 m |
| Flow | 43,200 m³/h |
| Speed | 250.00 rpm |
| Runner inlet diameter | 2.0000 m |
| Runner inlet width | 0.30000 m |
| Runner outlet diameter | 1.4000 m |
| Runner outlet width (axial area = πD₂B₂) | 0.50000 m |
| Guide vane angle | 18.000 ° |
| Area factor for blade thickness | 95.000 % |
| Water density | 1,000.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Runner inlet peripheral speed | 26.180 m/s |
| Inlet flow velocity | 6.7013 m/s |
| Inlet whirl velocity | 20.624 m/s |
| Absolute inlet velocity | 21.686 m/s |
| Runner blade inlet angle | 129.66 ° |
| Outlet peripheral speed | 18.326 m/s |
| Outlet flow velocity | 5.7439 m/s |
| Runner blade outlet angle | 17.403 ° |
| Hydraulic efficiency u₁V_w1/(gH) | 91.765 % |
| Power developed by the runner | 6,479.3 kW |
| Speed ratio | 0.76316 |
| Flow ratio | 0.19535 |
Open this example in the calculator and change any input.
Formula
\(u = \frac{\pi DN}{60}, \quad V_f = \frac{Q}{k\pi DB}, \quad V_{w1} = \frac{V_{f1}}{\tan\alpha_1}, \quad \tan\beta_1 = \frac{V_{f1}}{V_{w1} - u_1}, \quad \tan\beta_2 = \frac{V_{f2}}{u_2}\)
\(\eta_h = \frac{u_1V_{w1}}{gH}, \quad P = \rho Qu_1V_{w1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Net head | m |
| \(Q\) | Flow | m³/s |
| \(N\) | Speed | rad/s |
| \(D_1\) | Runner inlet diameter | m |
| \(B_1\) | Runner inlet width | m |
| \(D_2\) | Runner outlet diameter | m |
| \(B_2\) | Runner outlet width (axial area = πD₂B₂) | m |
| \(\alpha_1\) | Guide vane angle | rad |
| \(k\) | Area factor for blade thickness | - |
| \(\rho\) | Water density | kg/m³ |
| \(u_1\) | Runner inlet peripheral speed | m/s |
| \(V_{f1}\) | Inlet flow velocity | m/s |
| \(V_{w1}\) | Inlet whirl velocity | m/s |
| \(V_1\) | Absolute inlet velocity | m/s |
| \(\beta_1\) | Runner blade inlet angle | rad |
| \(u_2\) | Outlet peripheral speed | m/s |
| \(V_{f2}\) | Outlet flow velocity | m/s |
| \(\beta_2\) | Runner blade outlet angle | rad |
| \(\eta_h\) | Hydraulic efficiency u₁V_w1/(gH) | - |
| \(P\) | Power developed by the runner | W |
| \(u_1/\sqrt{2gH}\) | Speed ratio | - |
| \(V_{f1}/\sqrt{2gH}\) | Flow ratio | - |
Method and standards
Euler turbine equation with one-dimensional velocity triangles.
Where it is used
- Checking runner and guide vane geometry.
- Student and exam calculations on reaction turbines.
Common mistakes
- Measuring blade angles from the radial direction instead of the blade motion.
- Using the gross head.
Assumptions and limits
- One-dimensional flow, radial discharge.
Questions and answers
What is radial discharge?
Water leaves the runner with no whirl (V_w2 = 0), so all of its swirl is converted to work; real runners leave a little swirl at part load.
Which speed and flow ratios are usual?
Speed ratio u₁/√(2gH) of about 0.6–0.9 and flow ratio 0.15–0.3 for Francis runners.
What do the defaults represent?
A runner 2.0 m by 0.30 m wide at the inlet and 1.4 m at the outlet, 12 m³/s under 60 m at 250 rpm with 18° guide vanes and a 0.95 thickness factor.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10 (reaction turbines, velocity triangles and Euler equation)