Worked example
Example: Illustrative 40 m3/s at 80 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rated flow | 144,000 m³/h |
| Net head | 80.000 m |
| Inlet velocity coefficient (v = K_v√(2gH)) | 0.18000 - |
| Wrap angle | 345.00 ° |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inlet velocity | 7.1301 m/s |
| Inlet area | 5.6101 m² |
| Inlet diameter (circular) | 2,672.6 mm |
| Section area 90° from the inlet | 4.1466 m² |
| Section area 180° from the inlet | 2.6831 m² |
Open this example in the calculator and change any input.
Formula
\(v_{in} = K_v\sqrt{2gH}, \quad A_{in} = \frac{Q}{v_{in}}, \quad A(\varphi) = A_{in}\left(1 - \frac{\varphi}{\theta_{wrap}}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Rated flow | m³/s |
| \(H\) | Net head | m |
| \(K_v\) | Inlet velocity coefficient (v = K_v√(2gH)) | - |
| \(\theta_{wrap}\) | Wrap angle | rad |
| \(v_{in}\) | Inlet velocity | m/s |
| \(A_{in}\) | Inlet area | m² |
| \(D_{in}\) | Inlet diameter (circular) | m |
| \(A_{90}\) | Section area 90° from the inlet | m² |
| \(A_{180}\) | Section area 180° from the inlet | m² |
Method and standards
Spiral case.
Where it is used
- Preliminary hydro turbine layout.
- Comparing intake and penstock sizes.
Common mistakes
- Using gross head.
- Applying high-head coefficients to low-head units.
Assumptions and limits
- Constant mean velocity; uniform outflow to the stay vanes.
References
- Constant-velocity spiral case sizing
Questions and answers
Why does the spiral cross-section shrink?
Flow leaves into the stay vanes all round, so each successive section carries less flow at the same velocity.
Why are steel spirals used for high heads?
They contain high pressure; low-head plants often use concrete semi-spirals with lower velocities.
What do the defaults represent?
An illustrative Francis unit with 40 m³/s at 80 m net head, K_v = 0.18, 345° wrap.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gulliver and Arndt, Hydropower Engineering Handbook (McGraw-Hill, 1991)