Cross-Flow (Banki) Turbine Runner Diameter and Width

Jet velocity, runner diameter for a speed and the runner width for the flow of a cross-flow (Banki–Michell) turbine, with shaft power at an efficiency.

Thermal power plant

Inputs

Examples: Illustrative 0.5 m3/s at 20 m, 500 rpmVillage scheme 0.1 m3/s at 40 mLow head 1.5 m3/s at 8 m

Accepted: 18 to 72,000 m³/h
Accepted: 1 to 200 m
Accepted: 47.746 to 1,909.9 rpm
Accepted: 11.459 to 22.918 °
Accepted: 0.9 to 1
Accepted: 5 to 30 %
Accepted: 40 to 90 %

Results

C₁ = C_v√(2gH); best efficiency near u = ½C₁cosα₁, so D = 2u/ω. The jet, of thickness k_jD and width B, carries Q = C₁k_jDB. Cross-flow turbines suit 5–100 m heads and wide flow ranges (part-gate sections keep efficiency); efficiencies of 70–80 % are typical.

Jet velocity19.410m/s
Optimum peripheral speed9.3288m/s
Runner outer diameter356.34mm
Runner width (jet width)722.93mm
Shaft power76.492kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 0.5 m3/s at 20 m, 500 rpm. The inputs, in the units selected above:

InputValue
Design flow1,800.0 m³/h
Net head20.000 m
Runner speed500.00 rpm
Nozzle entry angle16.000 °
Nozzle velocity coefficient0.98000 -
Jet thickness as a fraction of runner diameter10.000 %
Turbine efficiency78.000 %

Applying the formula below gives:

ResultValue
Jet velocity19.410 m/s
Optimum peripheral speed9.3288 m/s
Runner outer diameter356.34 mm
Runner width (jet width)722.93 mm
Shaft power76.492 kW

Open this example in the calculator and change any input.

Formula

\(C_1 = C_v\sqrt{2gH}, \quad u = \tfrac12C_1\cos\alpha_1, \quad D = \frac{2u}{\omega}, \quad B = \frac{Q}{C_1k_jD}\)

Variables

Symbol Meaning SI unit
\(Q\) Design flow m³/s
\(H\) Net head m
\(N\) Runner speed rad/s
\(\alpha_1\) Nozzle entry angle rad
\(C_v\) Nozzle velocity coefficient -
\(k_j\) Jet thickness as a fraction of runner diameter -
\(\eta\) Turbine efficiency -
\(C_1\) Jet velocity m/s
\(u\) Optimum peripheral speed m/s
\(D\) Runner outer diameter m
\(B\) Runner width (jet width) m
\(P\) Shaft power W

Method and standards

Cross-flow turbine.

Where it is used

  • Micro and mini hydro schemes.
  • Canal drop and irrigation power.

Common mistakes

  • Using gross head.
  • Choosing a speed that gives a tiny or huge runner.

Assumptions and limits

  • Free jet; simple velocity triangle at entry.

References

  • Banki–Michell velocity relations

Questions and answers

Why use a cross-flow turbine?

It is simple to build locally and keeps efficiency over a wide range of flows when split into sections.

What sets the runner width?

The flow: for a given head and diameter, more flow needs a wider jet and runner.

What do the defaults represent?

An illustrative 0.5 m³/s at 20 m net head, runner at 500 rpm, 16° entry angle, jet thickness 0.1 D, 78 % efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mosonyi, Water Power Development, Vol. 2 (Akadémiai Kiadó, 1965), Nag, Power Plant Engineering, 4th ed. (McGraw-Hill, 2014)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.