FireCADCalc

Waste Heat Boiler Gas Outlet Temperature

Gas temperature leaving a waste heat boiler for a required steam output, from gas flow and specific heat, steam conditions and casing loss (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerEconomiser and air preheater

Inputs

Examples: 15 kg/s at 800 °C, 12 t/h saturated at 18 bar(a), feed 105 °CKiln gas 40 kg/s at 450 °C, 20 t/h at 25 bar(a) 300 °C, feed 130 °CEngine exhaust 5 kg/s at 400 °C, 2.5 t/h at 10 bar(a), feed 80 °C

Results

The gas would leave below the saturation temperature: the boiler cannot make this much steam from this gas; part of the duty must go to an economiser or the steam reduced.

Gas temperature leaving134.44°C
Heat to the steam13.676MW
Gas outlet minus saturation temperature-89.514K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 kg/s at 800 °C, 12 t/h saturated at 18 bar(a), feed 105 °C. The inputs, in the units selected above:

InputValue
Waste gas flow54,000 kg/h
Mean specific heat of the gas1.1500 kJ/(kg·K)
Gas temperature entering800.00 °C
Steam required12,000 kg/h
Steam pressure (absolute)18.000 bar
Steam conditionDry saturated
Superheated steam temperature250.00 °C
Feedwater temperature105.00 °C
Casing heat loss, share of the heat given up by the gas1.0000 %

Applying the formula below gives:

ResultValue
Gas temperature leaving340.42 °C
Heat to the steam7.8484 MW
Gas outlet minus saturation temperature133.30 K

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_s\,(h_s - h_{fw}) \qquad T_{g,2} = T_{g,1} - \frac{\dot Q}{(1 - \lambda)\,\dot m_g\,c_{p,g}} \qquad \Delta T = T_{g,2} - T_{sat}(p)\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) gas flow kg/s
\(c_{p,g}\) gas mean specific heat J/(kg·K)
\(T_{g,1}\) gas inlet temperature K
\(\dot m_s\) steam required kg/s
\(p\) steam pressure Pa
\(\text{state}\) saturated or superheated –
\(T_s\) superheat temperature K
\(T_{fw}\) feedwater temperature K
\(\lambda\) casing loss, share of the heat given up by the gas –
\(T_{g,2}\) gas outlet temperature K
\(\dot Q\) heat to steam W
\(\Delta T\) outlet minus saturation K
\(h_s, h_{fw}\) IF97 enthalpies J/kg

Method and standards

Heat balance on the gas side with a mean specific heat; steam and feedwater enthalpies from IAPWS-IF97.

Where it is used

  • Kiln, furnace and incinerator heat recovery.
  • Engine exhaust boilers.
  • Checking guarantee points.

Common mistakes

  • Using the specific heat at the inlet temperature only.
  • Forgetting blowdown: there is no blowdown input, so add the blowdown to the steam required.
  • Ignoring pinch: the evaporator can only cool gas to a few K above saturation.

Assumptions and limits

  • Single pass, no supplementary firing; pinch point not checked. For superheated steam the gas must enter hotter than the steam; the gas-to-steam profile in the superheater is not checked.
  • An outlet below saturation is reported with a warning, not rejected; the boiler alone cannot then make that steam.

References

  • IAPWS-IF97

Questions and answers

How far does 15 kg/s of 800 °C gas cool to make 12 t/h of saturated steam at 18 bar(a)?

To 340 °C with feed at 105 °C and 1 % casing loss: 7.85 MW to the steam, 133 K above saturation.

What if the outlet falls below saturation?

A boiler alone cannot do it: the rest of the duty needs an economiser, or less steam.

What specific heat should I use?

The mean for the gas between the two temperatures; about 1.1–1.2 kJ/(kg·K) for flue gases.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.