Worked example
Example: 15 kg/s at 800 °C, 12 t/h saturated at 18 bar(a), feed 105 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Waste gas flow | 54,000 kg/h |
| Mean specific heat of the gas | 1.1500 kJ/(kg·K) |
| Gas temperature entering | 800.00 °C |
| Steam required | 12,000 kg/h |
| Steam pressure (absolute) | 18.000 bar |
| Steam condition | Dry saturated |
| Superheated steam temperature | 250.00 °C |
| Feedwater temperature | 105.00 °C |
| Casing heat loss, share of the heat given up by the gas | 1.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas temperature leaving | 340.42 °C |
| Heat to the steam | 7.8484 MW |
| Gas outlet minus saturation temperature | 133.30 K |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_s\,(h_s - h_{fw}) \qquad T_{g,2} = T_{g,1} - \frac{\dot Q}{(1 - \lambda)\,\dot m_g\,c_{p,g}} \qquad \Delta T = T_{g,2} - T_{sat}(p)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | gas flow | kg/s |
| \(c_{p,g}\) | gas mean specific heat | J/(kg·K) |
| \(T_{g,1}\) | gas inlet temperature | K |
| \(\dot m_s\) | steam required | kg/s |
| \(p\) | steam pressure | Pa |
| \(\text{state}\) | saturated or superheated | – |
| \(T_s\) | superheat temperature | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(\lambda\) | casing loss, share of the heat given up by the gas | – |
| \(T_{g,2}\) | gas outlet temperature | K |
| \(\dot Q\) | heat to steam | W |
| \(\Delta T\) | outlet minus saturation | K |
| \(h_s, h_{fw}\) | IF97 enthalpies | J/kg |
Method and standards
Heat balance on the gas side with a mean specific heat; steam and feedwater enthalpies from IAPWS-IF97.
Where it is used
- Kiln, furnace and incinerator heat recovery.
- Engine exhaust boilers.
- Checking guarantee points.
Common mistakes
- Using the specific heat at the inlet temperature only.
- Forgetting blowdown: there is no blowdown input, so add the blowdown to the steam required.
- Ignoring pinch: the evaporator can only cool gas to a few K above saturation.
Assumptions and limits
- Single pass, no supplementary firing; pinch point not checked. For superheated steam the gas must enter hotter than the steam; the gas-to-steam profile in the superheater is not checked.
- An outlet below saturation is reported with a warning, not rejected; the boiler alone cannot then make that steam.
References
- IAPWS-IF97
Questions and answers
How far does 15 kg/s of 800 °C gas cool to make 12 t/h of saturated steam at 18 bar(a)?
To 340 °C with feed at 105 °C and 1 % casing loss: 7.85 MW to the steam, 133 K above saturation.
What if the outlet falls below saturation?
A boiler alone cannot do it: the rest of the duty needs an economiser, or less steam.
What specific heat should I use?
The mean for the gas between the two temperatures; about 1.1–1.2 kJ/(kg·K) for flue gases.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.